Europa Autoclave - 15 liters - Class B
- Secure payments: credit card, PayPal, and bank transfer
- Fast shipping: Poste Delivery Express, FedEx, UPS
- Customer support Whatsapp +39 371 43 61 201
Locazione Operativa
Accedi alle migliori tecnologie senza immobilizzare capitali.
| Durata | Canone mensile | Totale |
|---|---|---|
| 24 mesi | €218.81 + IVA | €5,251.44 + IVA |
| 30 mesi | €174.28 + IVA | €5,228.40 + IVA |
| 36 mesi | €151.93 + IVA | €5,469.48 + IVA |
| 48 mesi | €115.56 + IVA | €5,546.88 + IVA |
| 60 mesi | €95.95 + IVA | €5,757.00 + IVA |
* Importi al netto di IVA. Canoni calcolati sul prezzo del prodotto ex-IVA.
📋 Condizioni contrattuali (applicate da Grenke, non in carrello)
- Durata: da 24 a 60 mesi
- Importo noleggiabile: da €500 + IVA
- Pagamento: trimestrale anticipato tramite RID
- Assicurazione: 1,95% annuo sul valore del bene (fatturata direttamente da Grenke)
- Spese di incasso: € 0
-
Spese amministrative:
Fino a €12.500: €75 + IVA €12.501 – €25.000: €90 + IVA €25.001 – €100.000: €100 + IVA Oltre €100.000: €200 + IVA
- Riscatto a scadenza: Restituzione del bene oppure riscatto al 3% del valore iniziale del contratto
- Requisiti: Titolari di Partita IVA con almeno 2 anni di attività, con indirizzo in Italia
Le spese amministrative e assicurative sono gestite direttamente da Grenke e non vengono addebitate dal negozio. I canoni indicati sono stimati sul prezzo del prodotto e potranno essere confermati da Grenke in fase di istruttoria.
Europa Autoclave - 15 liters - Class B.
When discussing safety in a medical practice, the first aspect to consider is sterilization. The autoclave is a device that ensures physical and legal safety; for this very reason, the choice must be guided by rational criteria and professional assessments, not just economic considerations. Thanks to the new EN 13060 standards, choosing the right autoclave has become easier for every professional: they must select the appropriate certified model based on the materials to be sterilized. A Class B load autoclave can sterilize hollow items such as handpieces and turbines, as well as porous materials (gowns, gauze, etc.).
P.I.D. system (Proportional Integral Derivative)
It represents the highest expression of closed-loop control. It ensures constant control and monitoring of the entire functional system of the autoclave, automatically intervening in the event of anomalies in incorrect technical or electronic parameters.
Tanks inside the machine
If unsuitable liquids are accidentally added, all the autoclave tanks can be inspected and cleaned, as required by technical regulations. All autoclaves have an internal pure-water tank and a used-water tank. Each tank is equipped with probes to indicate maximum and minimum levels.
Preset temperatures
The temperatures set for the cycles of our autoclaves are 134°C and 121°C. The 134°C cycles are normally used to sterilize solid and ferrous materials. The 121°C cycles are used for thermoplastics and sensitive materials.
Ease of use
The sterilization cycle is selected by pressing one button and started by pressing another. The first lets you scroll through and view the data for each cycle on the large display, then select the most suitable one; the second automatically starts the entire sterilization cycle. In the event of any error or alarm, messages and LED indicators will draw your attention.
Fully automatic cycles
All stages are managed by the advanced board, equipped with a powerful microprocessor. Each stage (vacuum, preheating, exposure time, drying) is monitored, supported and managed automatically.
Unattended cycles with automatic shut-off
During sterilization cycles, an automatic function starts an anti-condensation phase and automatically switches the unit off if no operator is present at the end of the cycle.
Test cycles
Our autoclaves include test cycles for periodic checks using physical and functional methods. Helix test to assess vacuum performance in hollow items. Bowie & Dick test to assess vacuum performance in porous items. Vacuum test to assess the ability to maintain a vacuum.
Continuous cycle monitoring
A device ensures continuous control and monitoring of sterilization cycles. Any anomaly is detected and immediately halted if it could compromise the sterilization cycles. The operator is notified of the anomaly by a message.
All cycles ensure sterilization of Class B loads
All sterilization cycles feature a fractionated vacuum system, controls and parameters that ensure sterilization of Class B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization of every type of material processed.
Autoclave equipped with a built-in printer.
Supplied with a closed tray holder, 4 aluminum trays, 1 dual-purpose key (for removing the trays and adjusting the door), water inlet and outlet tubes, and a cleaning sponge.
Sales unit: 1 piece..
• External dimensions: 510 x 390 x 590 mm (W x H x D)
• Chamber dimensions: 245 x 320 mm (Ø x depth)
• Operating voltage 230 V - 50/60 Hz
• Maximum power consumption: 1700 W
• Weight: 54 kg
• Built-in printer: YES
• Manual closure: YES
• Provision for pure-water deionizer: YES
• PID system: YES
• Cycles: 121°C, wrapped
• Min.-max. operating pressure: 1.04 - 1.30
• Minimum total cycle duration *: 60 minutes (25 + 18 + 17)
• Cycles: 121°C, unwrapped
• Min.-max. operating pressure: 1.04 - 1.30
• Minimum total cycle duration *: 49 minutes (25 + 18 + 6)
• Cycles: 134°C, Flash
• Min.-max. operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 31 minutes (25 + 4 + 2)
• Cycles: 134°C, wrapped
• Min.-max. operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 47 minutes (25 + 5 + 17)
• Cycles: 134°C, unwrapped
• Min.-max. operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 36 minutes (25 + 5 + 6)
• Cycles: 134°C, Prion
• Min.-max. operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 62 minutes (25 + 20 + 17)
*Times expressed in minutes. Total time includes: vacuum, preheating, cycle and drying. Times are based on a fully loaded machine. All sterilization cycles have 3 vacuum stages. Vacuum and preheating time may vary, depending on the conditions of the autoclave, from 25 to 35 minutes.