Europa B Autoclave - 24 liters
- Secure payments: credit card, PayPal, and bank transfer
- Fast shipping: Poste Delivery Express, FedEx, UPS
- Customer support Whatsapp +39 371 43 61 201
Locazione Operativa
Accedi alle migliori tecnologie senza immobilizzare capitali.
| Durata | Canone mensile | Totale |
|---|---|---|
| 24 mesi | €285.32 + IVA | €6,847.68 + IVA |
| 30 mesi | €227.50 + IVA | €6,825.00 + IVA |
| 36 mesi | €195.89 + IVA | €7,052.04 + IVA |
| 48 mesi | €150.34 + IVA | €7,216.32 + IVA |
| 60 mesi | €124.13 + IVA | €7,447.80 + IVA |
* Importi al netto di IVA. Canoni calcolati sul prezzo del prodotto ex-IVA.
📋 Condizioni contrattuali (applicate da Grenke, non in carrello)
- Durata: da 24 a 60 mesi
- Importo noleggiabile: da €500 + IVA
- Pagamento: trimestrale anticipato tramite RID
- Assicurazione: 1,95% annuo sul valore del bene (fatturata direttamente da Grenke)
- Spese di incasso: € 0
-
Spese amministrative:
Fino a €12.500: €75 + IVA €12.501 – €25.000: €90 + IVA €25.001 – €100.000: €100 + IVA Oltre €100.000: €200 + IVA
- Riscatto a scadenza: Restituzione del bene oppure riscatto al 3% del valore iniziale del contratto
- Requisiti: Titolari di Partita IVA con almeno 2 anni di attività, con indirizzo in Italia
Le spese amministrative e assicurative sono gestite direttamente da Grenke e non vengono addebitate dal negozio. I canoni indicati sono stimati sul prezzo del prodotto e potranno essere confermati da Grenke in fase di istruttoria.
Europa B Autoclave - 24 liters.
When discussing safety in a medical practice, the first aspect to consider is sterilization. The autoclave is a device that ensures physical and legal safety; for this reason, the choice should be guided by rational criteria and professional assessment, not just economic considerations. Thanks to the new EN 13060 regulations, choosing the right autoclave has become easier for every professional: they must select the appropriate certified model based on the materials to be sterilized. A Class B load autoclave can sterilize hollow items such as handpieces and turbines, as well as porous materials (coats, gauze, etc.).
P.I.D. System (Proportional Integral Derivative)
This is the highest expression of closed-loop control. It ensures constant control and monitoring of the entire autoclave operating system, intervening automatically in the event of anomalies in incorrect technical or electronic parameters.
Tanks inside the machine
If unsuitable liquids are accidentally introduced, all the autoclave tanks can be inspected and cleaned, as required by technical regulations. All autoclaves have an internal pure water tank and a used water tank. Each tank is fitted with probes to signal maximum and minimum levels.
Preset Temperatures
The temperatures set for our autoclave cycles are 134°C and 121°C. 134°C cycles are generally used to sterilize solid and ferrous materials. 121°C cycles are used for thermoplastics and sensitive materials.
Easy to use
The sterilization cycle is selected by pressing one button and started by pressing another. The first lets you scroll through and view the data for each cycle on the large display, so you can then select the most suitable one; the second automatically starts the entire sterilization cycle. In the event of any error or alarm, messages and LED indicators will alert you.
Fully automatic cycles
All stages are managed by the advanced control board, which features a powerful microprocessor. Each stage (vacuum, preheating, exposure time, drying) is monitored, supported and managed automatically.
Unattended cycles with automatic shutoff
During sterilization cycles, an automatic function starts an anti-condensation phase and automatically switches the unit off if no operator is present at the end of the cycle.
Test cycles
Our autoclaves include test cycles for periodic checks using physical and functional testing systems. Helix test to assess the vacuum performance in hollow items. Bowie & Dick to assess the vacuum performance in porous items. Vacuum test to assess the vacuum-holding capacity.
Continuous cycle monitoring
A device ensures constant control and monitoring of sterilization cycles. Any anomaly is detected and immediately halted if it could compromise the sterilization cycles. The operator is notified of the anomaly by a message.
All cycles ensure sterilization of Class B loads
All sterilization cycles feature a fractional vacuum system, controls and parameters that ensure sterilization of Class B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization of every type of material being treated.
Integrated osmosis system
Water treatment that also removes the smallest pollutant particles, ensuring bacteriological purity. It works through an osmotic membrane that filters water at the molecular level.
Autoclave equipped with a built-in printer.
Supplied with a closed tray holder, 4 aluminum trays, 1 dual-purpose key (for removing the trays and adjusting the door), water inlet and outlet hoses, cleaning sponge and integrated osmosis system.
Sales unit: 1 piece..
• External dimensions: 510 x 390 x 730 mm (W x H x D)
• Chamber dimensions: 245 x 500 mm (Ø x depth)
• Operating voltage 230 V - 50/60 Hz
• Maximum power consumption: 2200 W
• Weight: 58 kg
• Built-in printer: YES
• Manual closure: YES
• Provision for pure-water deionizer: YES
• PID system: YES
• Cycles: 121°C Wrapped
• Minimum-maximum operating pressure: 1.04 - 1.30
Minimum total cycle duration *: 56 minutes (25 + 18 + 13)
• Cycles: 121°C Unwrapped
• Minimum-maximum operating pressure: 1.04 - 1.30
• Minimum total cycle duration *: 55 minutes (25 + 18 + 12)
• Cycles: 134°C Flash
• Minimum-maximum operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 33 minutes (25 + 4 + 4)
• Cycles: 134°C Wrapped
• Minimum-maximum operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 43 minutes (25 + 5 + 13)
• Cycles: 134°C Unwrapped
• Minimum-maximum operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 42 minutes (25 + 5 + 12)
• Cycles: 134°C Prion
• Minimum-maximum operating pressure: 2.02 - 2.38
• Minimum total cycle duration *: 58 minutes (25 + 20 + 13)
*Times expressed in minutes. The total time includes: vacuum, preheating, cycle and drying. Times are given with the machine fully loaded. All sterilization cycles have 3 vacuum stages. The vacuum and preheating time may vary, depending on the autoclave conditions, from 25 to 35 minutes.