Portable spirometer MIR Spirodoc with oximeter and MIR Spiro software
Spirometer with touch screen and 3D Oximeter: 6MWT, Sleep test, 24 h SpO2 Holter.
Flow meter with detachable head to facilitate oximetry testing during the 6-minute walk test.
This product is protected by two international patents: Design Copyright and Multifunctionality.
Real-time wireless tests also available on PC, via Bluetooth and USB. Lightweight and easy to carry on the go, with long-lasting rechargeable battery.
Unique functionality: configurable for both medical practice and home use
Real-time testing:
- Spirometry: FVC, VC, IVC, MVV, Pre/POST bronchodilator comparison
- 3D Oximetry: Spot Test (SpO2, BPM), 6MWT, Sleep Test, Holter Test for SpO2 24 h.
You take it anywhere:
LCD touch screen display, long-lasting rechargeable battery, memory of up to 10,000 spirometry tests (300 hours of oximetry), carrying case included.
ATS/ERS 2019 Compliance:
In addition, additional standards including ISO 26782 (for Spirometry), ISO 23747 (for PEF), ISO 80601 2 61 (for Oximetry), CE0476, FDA 510 (k)Real-time testing on PC (via USB or Bluetooth) and internal back-up memory.
Specifications:
- Display: LCD backlit touchscreen resolution 128x64 pixels
- Power supply: 3.7V, 1100mA rechargeable lithium-ion battery
- Data transmission: USB 2.0 On-The-Go and Bluetooth 2.1
- Accelerometer: triaxial ± 2g, 400Hz
- Dimensions and Weight: camera body 101x48x16mm, 99g; Turbine Holder 46x47x24mm, 17g
- Battery Charger (opt.): Input 100VAC - 240VAC, 50Hz-60Hz; Output 5VDC, 500mA, micro USB type B
Spirometer:
- Flow sensor: bidirectional turbine
- Flow measurement: ±16L/s
- Volume accuracy: ±3% or 50mL
- Flow accuracy: ±5% or 200mL/s
- Dynamic resistance at 12L/s: Temperature sensor: semi-conduction (0-45°C)
Spirometry parameters:
FVC, FEV1, FEV1/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25%-75%, FET, Lung Age, Extr. Vol., FIVC, FIV1, FIV1/FIVC%, PIF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, measured MVV, calculated MVV
Pulse oximeter:
- SpO2 measurement: 0-99%
- SpO2 accuracy: ±2% between 70-99%SpO2
- Pulse rate measurement: 30-254BPM
- Pulse rate accuracy: ±2BPM or 2%, whichever is greater
Basic pulse oximetry parameters:
SpO2 [Basale, Min, Max, Media], [Basale, Min, Max, Media]Pulse Rate , T90% [SpO25%], ΔIndex [12s], SpO2 Events, [Bradicardia, Tachicardia]Pulse Rate Events , Number of Steps, [VMU]Movement , Recording Time, Analysis Time
6-minute walk test parameters:
O2-Gap, Estimated Distance, Distance Traveled, Theoretical Distance [Min, Standard],TΔ2% [SpO2≥2%], TΔ4% [ΔSpO2≥4%], [Riposo, Cammino, Recupero]Time , Desaturation Area/Distance, Borg [Inizio, Fine, Diff.]Dyspnea , Borg [Inizio, Fine, Diff.]Fatigue , [Sistolica, Diastolica]Blood Pressure , Oxygen Administered
Oximetry parameters in sleep:
Body position, SpO2 events, Desaturation index (ODI), [Valore, Durata, Nadir]desaturation, ΔSpO2 [Min Drop, Max Drop], Pulse variation, Pulse index, NOD89% [SpO25min], NOD4% [SpO2 Basale-4%; >5min], NOD90% [SpO25min]
Minimum PC requirements for winspiroPRO software:
- Microsoft Windows 7,Vista,XP
- Adobe Reader software for PC
- Minimum monitor resolution: 1024 x 768
- Hard Disk Space Required: 500MB
- CD-ROM drive
-USB port
Technical assistance:
We are an authorized MIRservice center, so in the event of problems and/or failures both within the warranty period and outside of it, you can refer directly to us by calling the number 0105761476
Equipment:
-Custody
- USB cable
-Software
- Reusable turbine
- Fingertip oximetry probe
- Belt with dedicated shell for test execution