Description
High frequency electrosurgical unit that can be used to simultaneously perform monopolar and bipolar surgery.
DOUBLE OPERATIONAL ACTIVITY
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations
CONTROLLED CUTTING PROCEDURES
- intensified cutting currents for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current
DOUBLE CONTROLLED COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or pedal
BROAD BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic start and stop of coagulation that can be activated separately
TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of the contact impedance between the patient's body and the neutral plate continuously verified by the Skin Plate Electronic Control (SPEC)
- continuous monitoring of radio frequency leakage current
- variations in mains voltage automatically compensated before starting the supply of power and radio frequency
CUSTOMIZED PROCEDURES
- independent choice of coagulation currents and power levels of each of the two operators
- ten personal procedures that can be configured and immediately recalled
CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for piloted connections of argon plasma units and fume extractors
AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of the malfunctions found.
- OUTPATIENT SURGERY
- GENERAL SURGERY
- PEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNECOLOGY
- NEUROSURGERY
- ORTHOPEDICS
- ENT
- PNEUMOLOGY
- UROLOGY
- VETERINARY
1 pc.
Technical features:
- Maximum out power monopolar pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
- Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
- Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm
- Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
- Maximum out power monopolar coag SPRAY 100 W - 2000 Ohm
- Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
- Maximum out power bipolar CUT 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
- Working frequency monopolar/bipolar: 425 kHz / 525 kHz
- Patient circuit: F
- Selectable input voltage: 115-230 Vac
- Mains frequency: 50-60 Hz
- Electrical input voltage: 1000 VA
- Size WxHxD: 470 x 150 x 400 mm
- Weight: 17.5 kgs
- Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
- Electrical Class: I CF, MDD 93/42/EC Class: II b
Equipment:
1 - 5 m power cable
1 - Autoclavable handpiece with two buttons (30536)
5 - Sterile handpiece cold with two buttons (30551)
1 - Plate cable (30559)
5 - Rem disposable plates (30493)
2 - HP double watertight pedal set
3 - Short blade electrode 7 cm
3 - Blade electrode 16 cm long
3 - Short ball electrode Ø 4 mm, 6 cm
1 - Electrode cleaning sponge
1 - User manual (IT, GB)
1 - Service manual (IT, GB)
DOUBLE OPERATIONAL ACTIVITY
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations
CONTROLLED CUTTING PROCEDURES
- intensified cutting currents for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current
DOUBLE CONTROLLED COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or pedal
BROAD BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic start and stop of coagulation that can be activated separately
TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of the contact impedance between the patient's body and the neutral plate continuously verified by the Skin Plate Electronic Control (SPEC)
- continuous monitoring of radio frequency leakage current
- variations in mains voltage automatically compensated before starting the supply of power and radio frequency
CUSTOMIZED PROCEDURES
- independent choice of coagulation currents and power levels of each of the two operators
- ten personal procedures that can be configured and immediately recalled
CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for piloted connections of argon plasma units and fume extractors
AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of the malfunctions found.
- OUTPATIENT SURGERY
- GENERAL SURGERY
- PEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNECOLOGY
- NEUROSURGERY
- ORTHOPEDICS
- ENT
- PNEUMOLOGY
- UROLOGY
- VETERINARY
1 pc.
Technical features:
- Maximum out power monopolar pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
- Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
- Maximum out power monopolar coag SPEEDY: 120 W - 500 Ohm
- Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
- Maximum out power monopolar coag SPRAY 100 W - 2000 Ohm
- Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
- Maximum out power bipolar CUT 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
- Working frequency monopolar/bipolar: 425 kHz / 525 kHz
- Patient circuit: F
- Selectable input voltage: 115-230 Vac
- Mains frequency: 50-60 Hz
- Electrical input voltage: 1000 VA
- Size WxHxD: 470 x 150 x 400 mm
- Weight: 17.5 kgs
- Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
- Electrical Class: I CF, MDD 93/42/EC Class: II b
Equipment:
1 - 5 m power cable
1 - Autoclavable handpiece with two buttons (30536)
5 - Sterile handpiece cold with two buttons (30551)
1 - Plate cable (30559)
5 - Rem disposable plates (30493)
2 - HP double watertight pedal set
3 - Short blade electrode 7 cm
3 - Blade electrode 16 cm long
3 - Short ball electrode Ø 4 mm, 6 cm
1 - Electrode cleaning sponge
1 - User manual (IT, GB)
1 - Service manual (IT, GB)
Data sheet