Security policy
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
Description
- Large LCD display for viewing waveforms and data
- High resolution thermal matrix printer
- Frequency response 150 Hz
- Continuous printing capability of ECG trace and annotations including lead, sensitivity, print speed and filter status
- High resolution digital filter prevents baseline drift without altering the ECG waveform
- Floating input circuit compliant with IEC safety standard
- Rechargeable battery (more than 50 tests per charge)
- Internal software: GB, IT, FR, ES, DE, TR.
- Manual: GB, IT, ES.
1 pc.
Technical features:
ECG
- Type of safety: Class I, applied parts type CF (applied parts with defibrillation protection)
- Leads: 12 standard
- Input: floating input circuit and defibrillation protection
- Patient leakage current: - Sampling frequency: 800Hz
- A/D conversion: 12bit
- Response frequency: 0.05Hz~150Hz (-3dB, +0.4dB)
- Time constant: >3.2s
- CMRR: >60dB, >100dB (add filter)
- Bias voltage: ±500mV
- Sound level:
Filters
- Interference filter: EMG 35Hz (-3dB)
- AC filter: 50Hz/60Hz (=20dB)
Waveform
- Recording mode: thermal printer
- Paper type: 50mm × 20m
- Sensitivity: 5, 10, 20 mm/mV
- Printing speed:
- Automatic recording: automatic change of leads
- Rhythm recording: 25 mm/s, 50 mm/s
- Manual recording: 25 mm/s, 50 mm/s
Diet
- AC 110-220V, 50/60 Hz
- DC lithium battery 7.4V, 2000 mAh
Fuse
- 2 pcs Ø5×20mm AC time lag; T250mA/250V (Power supply:220V)
Form
- Dimensions: 315 x 215 x 77 mm
- Weight: 1.5kg
Equipment:
- ECG cable
- 1 set of peripheral clamp electrodes
- 1 set of precordial electrodes
- Earth cable
- Alimentation cable
- Toilet paper
- High resolution thermal matrix printer
- Frequency response 150 Hz
- Continuous printing capability of ECG trace and annotations including lead, sensitivity, print speed and filter status
- High resolution digital filter prevents baseline drift without altering the ECG waveform
- Floating input circuit compliant with IEC safety standard
- Rechargeable battery (more than 50 tests per charge)
- Internal software: GB, IT, FR, ES, DE, TR.
- Manual: GB, IT, ES.
1 pc.
Technical features:
ECG
- Type of safety: Class I, applied parts type CF (applied parts with defibrillation protection)
- Leads: 12 standard
- Input: floating input circuit and defibrillation protection
- Patient leakage current: - Sampling frequency: 800Hz
- A/D conversion: 12bit
- Response frequency: 0.05Hz~150Hz (-3dB, +0.4dB)
- Time constant: >3.2s
- CMRR: >60dB, >100dB (add filter)
- Bias voltage: ±500mV
- Sound level:
Filters
- Interference filter: EMG 35Hz (-3dB)
- AC filter: 50Hz/60Hz (=20dB)
Waveform
- Recording mode: thermal printer
- Paper type: 50mm × 20m
- Sensitivity: 5, 10, 20 mm/mV
- Printing speed:
- Automatic recording: automatic change of leads
- Rhythm recording: 25 mm/s, 50 mm/s
- Manual recording: 25 mm/s, 50 mm/s
Diet
- AC 110-220V, 50/60 Hz
- DC lithium battery 7.4V, 2000 mAh
Fuse
- 2 pcs Ø5×20mm AC time lag; T250mA/250V (Power supply:220V)
Form
- Dimensions: 315 x 215 x 77 mm
- Weight: 1.5kg
Equipment:
- ECG cable
- 1 set of peripheral clamp electrodes
- 1 set of precordial electrodes
- Earth cable
- Alimentation cable
- Toilet paper
Data sheet
3 other products in the same category: