Description
A high quality multifunctional professional tool.
DefiMonitor XD combines a compact and reliable design, the highest level of security and easy use.
Range of 8 manual defibrillators (XD1, XD3, XD10, XD30) or manual + AED (XD100,
Supplied with adult/pediatric electrodes, disposable adult adhesive electrodes, a connection cable, an ECG cable, a power cable, 1 tube of gel, 1 roll of paper.
Standard software: GB, FR, DE, IT ,ES, KT, PT, RO, TR, CN.
Manual: GB, IT (DE, ES, PT, RU, UA on request).
Other software and manuals available upon request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US.
Dimensions: 33 x 29 x 16 cm
1 pc.
Technical features:
Defibrillation
- Pulse: biphasic, regulated by current
- Energy (automatic mode) 140-360 J
- Manual energy levels: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J
- Charging times: - Cardioversion: manual activation, QRS marker
ECG
- Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
- Patient resistance: 23-200 Ohm
- Heart rate: 30-300 par min
VF detection:
- VF detection
- Analysis time 7-12 sec
- VF threshold 200 µV
- Asystole threshold - Artifact detection, pacemaker
Pacers
- Transthoracic pacemaker
- Modes: fixed, on demand, overdrive
Thermal printer
- Resolution: 200 dpi
- Feedrate 25 mm/s, 50 mm/s
TFT monitor, LCD-Blue-mode
- 115 x 86 mm (diagonal 4.7''/120 mm)
- 320 x 240 pixels
Electrodes
- Adhesive electrodes, surface durability 3 years
- Cable length 3.5 m SavePads Connect
Data management
- 2 GB removable memory
- Data recording Voice recording > 90 h
Diet
- Voltage 90-264V, 50-60 Hz
Rechargeable NiCD battery:
- Capacity: 1.4 Ah Voltage: 12 V
- Discharges: 70-200 J
Monitoring: 3h Charging time: 2.5h
Resuscitation guidelines
- AHA/ERC of your choice
Standards
- IEC60601-1:1988 + A1:1991 + A2:1995 (Electrical safety of medical electrical instruments)
- IEC60601-1-2:2001 (Electromagnetic compatibility)
- IEC60601-1-4:1996 + A10:1999 (Programmable medical electrical systems)
- IEC60601-2-4 :2002 (Defibrillators)
- EN1789:2003 (Ambulance standard)
- Type of protection class IP33
DefiMonitor XD combines a compact and reliable design, the highest level of security and easy use.
Range of 8 manual defibrillators (XD1, XD3, XD10, XD30) or manual + AED (XD100,
Supplied with adult/pediatric electrodes, disposable adult adhesive electrodes, a connection cable, an ECG cable, a power cable, 1 tube of gel, 1 roll of paper.
Standard software: GB, FR, DE, IT ,ES, KT, PT, RO, TR, CN.
Manual: GB, IT (DE, ES, PT, RU, UA on request).
Other software and manuals available upon request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US.
Dimensions: 33 x 29 x 16 cm
1 pc.
Technical features:
Defibrillation
- Pulse: biphasic, regulated by current
- Energy (automatic mode) 140-360 J
- Manual energy levels: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J
- Charging times: - Cardioversion: manual activation, QRS marker
ECG
- Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
- Patient resistance: 23-200 Ohm
- Heart rate: 30-300 par min
VF detection:
- VF detection
- Analysis time 7-12 sec
- VF threshold 200 µV
- Asystole threshold - Artifact detection, pacemaker
Pacers
- Transthoracic pacemaker
- Modes: fixed, on demand, overdrive
Thermal printer
- Resolution: 200 dpi
- Feedrate 25 mm/s, 50 mm/s
TFT monitor, LCD-Blue-mode
- 115 x 86 mm (diagonal 4.7''/120 mm)
- 320 x 240 pixels
Electrodes
- Adhesive electrodes, surface durability 3 years
- Cable length 3.5 m SavePads Connect
Data management
- 2 GB removable memory
- Data recording Voice recording > 90 h
Diet
- Voltage 90-264V, 50-60 Hz
Rechargeable NiCD battery:
- Capacity: 1.4 Ah Voltage: 12 V
- Discharges: 70-200 J
Monitoring: 3h Charging time: 2.5h
Resuscitation guidelines
- AHA/ERC of your choice
Standards
- IEC60601-1:1988 + A1:1991 + A2:1995 (Electrical safety of medical electrical instruments)
- IEC60601-1-2:2001 (Electromagnetic compatibility)
- IEC60601-1-4:1996 + A10:1999 (Programmable medical electrical systems)
- IEC60601-2-4 :2002 (Defibrillators)
- EN1789:2003 (Ambulance standard)
- Type of protection class IP33