DefiMonitor XD Manual Defibrillator with SpO2 and Pacer
zoom_out_map
chevron_left chevron_right

DefiMonitor XD Manual Defibrillator with SpO2 and Pacer

9,547.37 Tax included

7,825.71 Tax excluded

new_releases Shipping in approximately 30 days.
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)
Description
A high-quality professional multifunction tool.
DefiMonitor XD combines a compact and reliable design, the highest level of security and easy use.

Range of 8 manual (XD1, XD3, XD10, XD30) or manual + AED defibrillators (XD100, XD300, XD110, XD330) with or without SpO2 and external pacer.

Supplied with adult/pediatric electrodes, disposable adult adhesive pads, a connection cable, an ECG cable, a power cable, 1 gel tube, 1 roll of paper.

Standard software: GB, FR, DE, IT ,ES, KT, PT, RO, TR, CN.
Manual: GB, IT (DE, ES, PT, RU, UA on request).
Other software and manuals available on request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US.

Dimensions: 33 x 29 x 16 cm

1 pc.

Specifications:
Defibrillation
- Pulse: biphasic, current-regulated
- Energy (automatic mode) 140-360 J
- Manual energy levels: 5 J, 10 J, 20 J, 30 J, 50 J, 100 J, 200 J, 300 J, 360 J
- Charging times: - Cardioversion: manual activation, QRS marker

ECG
-Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
- Patient resistance: 23-200 Ohm
- Heart rate: 30-300 par min

Pulse oximeter
- Type Nellcor, Oximax

Pacer
- Transthoracic pacemaker
- Mode: Fixed, On-Demand, Overdrive

Thermal Printer
- Resolution: 200 dpi
- Feed rate 25 mm/s, 50 mm/s

TFT monitor, LCD-Blue-mode
- 115 x 86 mm (4.7''/120 mm diagonal)
- 320 x 240 pixels

Electrodes
- Adhesive electrodes, surface life 3 years
- Cable length 3.5 m SavePads Connect

Data management
- Removable memory 2 Gb
- Data recording Voice recording > 75 h

Feeding
- Voltage 90-264V, 50-60 Hz

Rechargeable NiCD battery:
- Capacity: 1.4 Ah Voltage: 12 V
- Discharges: 70-200 J
Monitoring: 3 h Charging Time: 2.5 h

Resuscitation guidelines
- AHA/ERC of your choice

Rules
- IEC60601-1:1988 + A1:1991 + A2:1995 (Electrical Safety of Medical Electrical Instruments)
- IEC60601-1-2:2001 (Electromagnetic compatibility)
- IEC60601-1-4:1996 + A10:1999 (Programmable Medical Electrical Systems)
- IEC60601-2-4 :2002 (Defibrillators)
- EN1789:2003 (Ambulance standard)
- Protection type class IP33
Data sheet
GIMA
DF35373
New
8023279353730