Secure payments
by credit card, Paypal and bank transfer.
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
via Whatsapp + 39.371.43.61.201
Description
It allows you to detect saturation, heartbeat and perfusion from the patient's finger (finger 10-22 mm) in a hospital or outpatient setting.
Key features:
- SpO2 and pulse detection
- Pulse histogram
- calculation of perfusion index. The perfusion index is a numerical value that indicates the intensity of the pulse at the point where the sensor is placed. It is a relative value that varies from patient to patient and depending on the area in which the sensor is placed
- great precision and repeatability of the results: the devices are produced by Gima (in factories in R.P.C.) under strict quality controls guaranteed by an Italian certification body (CE 0476 CERMET)
- Accuracy from the first reading in seconds thanks to a
a unique noise filter system - great stability during measurement (finger bending, Parkinson's disease, hand movements, button pressing)
- visual and acoustic alarms
- automatic switching on and off (if the finger is not inserted)
- Low charge indicator
- Manual in 9 languages (GB, FR, IT, ES, DE, GR, PT, PL, AR)
- 50 hours of operation with full batteries
- Supplied in a plastic case with batteries and case
Specifications:
-Pulsations:
- Range: 30-240 bpm
- Accuracy: ± 2 bpm (2%)
- Resolution: 1bpm
- SpO2:
- Field: 35%-99%
- Accuracy: ± 2% (75-99%)/± 3% (50-75%)
- Resolution: 1%
- Perfusion index:
- Range: 0-20%
- Accuracy: ± 0.1% (0.2-2%)/± 0.2% (2-10%)
- Resolution: 0.1%
- Alarm: SpO2: Lower limit 90%
- Pulse alarm: low: 120 bpm
- Power supply: 1.5V (AAA) alkaline batteries x 2
- Standards: IEC 60601-1-2 Class II
- LCD display: oxygen saturation, beat, battery level indication
- Size: 6.6 x 3.6 x 3.3 cm
- Weight: 60 g including batteries
- Italian production (made in P.R.C.)
- BD/RDM: 237641
- NDT: Z1203020408
- Paraf: 926562101
- EAN13: 8023279342826
- GMDN: 45607
Key features:
- SpO2 and pulse detection
- Pulse histogram
- calculation of perfusion index. The perfusion index is a numerical value that indicates the intensity of the pulse at the point where the sensor is placed. It is a relative value that varies from patient to patient and depending on the area in which the sensor is placed
- great precision and repeatability of the results: the devices are produced by Gima (in factories in R.P.C.) under strict quality controls guaranteed by an Italian certification body (CE 0476 CERMET)
- Accuracy from the first reading in seconds thanks to a
a unique noise filter system - great stability during measurement (finger bending, Parkinson's disease, hand movements, button pressing)
- visual and acoustic alarms
- automatic switching on and off (if the finger is not inserted)
- Low charge indicator
- Manual in 9 languages (GB, FR, IT, ES, DE, GR, PT, PL, AR)
- 50 hours of operation with full batteries
- Supplied in a plastic case with batteries and case
Specifications:
-Pulsations:
- Range: 30-240 bpm
- Accuracy: ± 2 bpm (2%)
- Resolution: 1bpm
- SpO2:
- Field: 35%-99%
- Accuracy: ± 2% (75-99%)/± 3% (50-75%)
- Resolution: 1%
- Perfusion index:
- Range: 0-20%
- Accuracy: ± 0.1% (0.2-2%)/± 0.2% (2-10%)
- Resolution: 0.1%
- Alarm: SpO2: Lower limit 90%
- Pulse alarm: low: 120 bpm
- Power supply: 1.5V (AAA) alkaline batteries x 2
- Standards: IEC 60601-1-2 Class II
- LCD display: oxygen saturation, beat, battery level indication
- Size: 6.6 x 3.6 x 3.3 cm
- Weight: 60 g including batteries
- Italian production (made in P.R.C.)
- BD/RDM: 237641
- NDT: Z1203020408
- Paraf: 926562101
- EAN13: 8023279342826
- GMDN: 45607
Data sheet
6 other products in the same category: