Diatherm mb 200f - mono-bipolar 200 watt
zoom_out_map
chevron_left chevron_right

Diatherm mb 200f - mono-bipolar 200 watt

€2,726.18 VAT included

€2,234.57 VAT excluded

new_releases Shipping in 7/10 days.
Secure payments
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
Description
High-frequency electrosurgical unit suitable for monopolar and bipolar precision surgery and microsurgery without tissue alterations.
It allows surgical treatments to be carried out with programmable operating times in milliseconds, or to operate in traditional mode.
MB FLASH allows pure CUT cutting, BLEND cutting-coagulation, incisions with reduced ENHANCED carbonization production, FORCED COAG surface coagulation, deep coagulation in the absence of SOFT COAG necrosis and BIPOLAR COAG bipolar coagulation.

The digital reading of the power output and the monitoring of the operating functions by means of a microcontroller ensure the absolute reliability of the working conditions.
The connection of the neutral electrode is constantly monitored.
The safety of the plate/patient contact is controlled by a bipartite neutral electrode.
The possibility of controlling the functions and power delivery from the electrode handpiece allows the execution of surgical interventions without diverting attention from the operating field.

Features:
- Plaque-patient contact control
- allows use of a bipartite neutral electrode
- minimally invasive surgical treatment
- independent monopolar and bipolar functions
- automatic start/stop in bipolar coagulation
- Planning of working conditions
- Power delivery with pedal and/or handpiece
- Digital power control and display
- Adjustment of the intensity of the sound emission
- Adjustable power increase
- Setting of emission time and RF power pulse interval

1 pc.

Specifications:
Max CUT Power: 200W-250Ohm
Max BLEND power: 120 W-200 Ohm
Max ENHANCED Power: 120W-250Ohm
Max power FORCED COAG: 150 W-150 Ohm
Max power SOFT COAG: 90 W-100 Ohm
BIPOLAR COAG max power: 80 W-50 Ohm
Working frequency: 600 kHz
RF Power Pulse Emission Time: 10ms - 30sec
RF Power Pulse Range: 1 - 9
Patient circuit: F
Selectable input voltage: 115 - 230 Vac
Mains frequency: 50 - 60 Hz
Maximum power consumption: 350 VA
Dimensions WxHxD: 370 x 144 x 319 mm
Weight: 6 kg
Controls: Plate/patient circuit control, Emitted power control, Self-diagnosis
Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF, DDM 93/42/EC Class: II b

Equipment:
MB Sterilizable Two-Button Handpiece (30536)
Flexible Steel Blank Plate with Cable (30555-30560)
MB Waterproof Pedal (30577)
Kit of 10 standard short electrodes Ø 2.4 mm
3 needle electrodes + 3 blade electrodes + 3 ball electrodes 7 cm
2 disposable plates (30562)
Power cable 5m
Microsurgery Handpiece (30552)
Microsurgery needles 10 pcs.
Manual: GB, IT
Data sheet
GIMA
CH30633
New
8023279306330