Description

By means of the Ermenrich Ping MK50 digital clamp meter, electrical devices can be diagnosed and the characteristics of electrical circuits measured. Both AC and DC current are measured without breaking the circuit. The device also functions as a voltmeter, ohmmeter, thermocouple, and duty cycle, frequency, and capacitance meter. Extensive functionality, high measurement accuracy and easy operation make the Ermenrich Ping MK50 digital clamp meter the excellent choice for performing professional electrical work and maintaining the functionality of household appliances and electrical wiring in domestic environments.

All measurements are made using the true RMS method, which is true root mean square value that increases accuracy. When measuring DC current, you can use the DCA Zero function to compensate for residual magnetization. The device is intelligent, i.e. it detects and measures the incoming signal in fully automatic mode: The Smart function allows the measurement of continuity, voltage and resistance.

The continuity function is used for diagnostics that allows you to check the continuity of the electrical circuit and detect open circuits and short circuits. A separate diagnostic function is used to determine diode failures. Current clamps can also function as dangerous voltage detectors: The NCV function is required to find hidden wiring and electrical outlets. Features a phase detector.

The device is compact, great for working in hard-to-reach places, and features a built-in flashlight. Battery powered.

Key features:

  • AC and DC current measurement
  • Additional measurement functions: ohmmeter, voltmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
  • Smart function: automatic operation for continuity, resistance and voltage measurement modes
  • NCV (Dangerous Voltage Detection), Continuity Test (Circuit Continuity Detection), Diode Test, Phase Detection Function
  • Data Lock function and memory of minimum/maximum values to simplify work with measurement results
  • Integrated flashlight for working in dark environments

The kit includes:

  • Current clamp meter
  • Test Probes
  • Case
  • User Manual & Warranty Card
BrandErmenrich
Guarantee5 лет
EAN5905555017488
Package size (LxWxH)22x11x4 cm
Shipping Weight0.45 kg
Select the measurement limitAutomatic
Basic functions voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, thermocouple
DC voltage measurement limit600 mV/6 V/60 V/600 V: Error ±(0.5%+5)
AC voltage measurement limit600 mV/6 V/60 V/600 V: Error ±(0.8%+5)
DC Current Measurement Limit60/600 A: Error ±(2.5%+5)
AC Current Measurement Limit60/600 A: ± error (2.5%+5)
Resistance measurement limit600 Ω/6 kΩ/60 kΩ/600 kΩ/6 MΩ/60 MΩ: ±(1.0%+5) error
Capacity measurement limit6 nF/60 nF/600 nF/6 μF/60 μF/600 μF/6 mF/60 mF: ± error (4.0%+5)
Frequency measurement limits100 Hz/1000 Hz/10 kHz/100 kHz/1 MHz/10 MHz: Error ±(1.0%+3)
Duty cycle measurement range1–99%: Error ±(3.0%+3)
Cable mappingYes
Diode TesterYes
Non-contact phase tester (NCV)Yes
True RMS value Yes
Hold function (fixed measurement)Yes
Limit value function (Min/Max)Yes
DCA ZeroYes
Automatic recognition function (Smart)+ (DC and AC voltage only, resistance and capacitance)
Phase detector (live)Yes
Overvoltage categoryCAT III 600 V
Maximum display value6000
Display backlightYes
Graphic scaleYes
Flashing lightYes
Safety standardsEN61010-1,-2-030 EN61010-2-033 EN61326-1
Operating Temperature Range, °C-40 — 1000
Continuity testing+, along with resistance measurement mode (600 Ω)
Feeding3 x AAA batteries (not included)
Low battery indicatorYes
Auto Power OffYes