The Ermenrich Ping ET60 Earth Resistance Tester is a device designed to measure ground resistance in a range of 0 to 4 kΩ. It has a built-in LCD screen, three test leads of various lengths, and two grounding stakes. The device runs on batteries, has an automatic shut-off function and warns you of the need to replace the batteries if their charge is insufficient. It is recommended to take measurements and diagnostics of equipment with a high battery charge level, otherwise, the results may be unreliable.
The device stores the measurements in memory, records the maximum, minimum, and average values, and performs the corresponding measurements using a reference value. The Data Retention feature is designed to "freeze" the measurement results on the device's screen in situations where you need to work on them later.
Ermenrich Ping ET60 is a measuring device used to test electrical distribution lines, plan lightning protection systems, diagnose high-voltage poles, buildings, communication stations, indoor wiring, electrical equipment, etc. It has a high measurement accuracy and is suitable for use in professional work environments.
Key features:
- Measurement of earth resistance using the DC conversion method
- Measurement of the earth voltage using the numerical mean rectification method
- Memory for 100 measurement groups and storage of minimum, maximum and average values
- On-screen read hold function, calculation based on reference values
- Powered by standard batteries, automatic shut-off function and low battery warning
Kit Includes:
- Earth Resistance Tester
- Test leads – 3 pcs.
- Auxiliary grounding pegs – 2 pcs.
- Case bag
- User Manual & Warranty Card
Brand | Ermenrich |
Guarantee | 5 лет |
EAN | 5905555017402 |
Package size (LxWxH) | 33x26x9 cm |
Shipping Weight | 2.36 kg |
Earth resistance measurement range | 0–29.99 Ω: Error (±2%+6), Resolution 0.01 Ω 30–99.9 Ω: Error (±3%+3), Resolution 0.1 Ω 100–999 Ω: Error (±3%+3), Resolution 1 Ω 1.00–4.00 kΩ: Error (±3%+3), Resolution 10 Ω |
Ground voltage | 0–200 V (50–60 Hz): Accuracy (±1%+5), 0.1 V resolution |
Measurement method | two-conductor, three-conductor |
Earth resistance measurement parameters | test current 3 mA, 800 Hz |
Memory | 100 groups |
Average value memory (AVG) | Yes |
Relative value measurement (REL) | Yes |
Overvoltage category | CAT III 1000 V, CAT IV 600 V |
Display | Yes |
Display backlight | Yes |
Graphic scale | Yes |
Safety standards | EN61010-1, EN61557-3, EN61326-1 |
Data save/read function | Yes |
Data Retention Function | Yes |
Limit value memory (Min/Max) | Yes |
Feeding | 8 x AA batteries (not included) |
Low battery indicator | Yes |
Auto Power Off | Yes |