ICT rapid test for the determination of the presence of Dirofilaria Immitis antigens in dogs or cats.
 
- Sample: Serum, plasma, whole blood
- Sensitivity: >99 %
- Specificity: 100 %
- Analysis Time: 5~10 minutes
- Pack: 10 Tests
 
The Canine Heartworm Ag (CHW Ag) Test is a rapid immunochromatographic test used for the qualitative detection of antigens in the dog's blood, serum or plasma.
 
Working Principle:
The lateral flow immunochromatographic assay has a test window. The test window has a T-zone (test) and C-zone (control) that are invisible before specimen is added. When the specimen is applied to the well, the liquid flows laterally onto the surface of the test strip. If there is sufficient antigen presence in the sample, a visible band will appear in the T zone. Band C, which acts as a procedural control, should always appear after a sample has been applied and indicates a valid result.
 
Kit Components:
- 10 foil pouches, each containing a cassette, pipette and desiccant
- 1 container of thinner
- 1 x Instruction manual
 
Sample preparation:
Collect whole blood, serum, or plasma in accordance with normal laboratory procedures.
For serum or plasma sample: enterthe dog's blood sample to obtain serum or plasma; Use serum or plasma directly for analysis.
Note: It is recommended to use serum or plasma to increase the sensitivity of the test.
 
Analysis procedure:
Open the foil pouch and remove the test cassette and place it on a clean, flat surface.
Use the provided pipette to transfer 1 drop of the sample to the well of the test cassette. Make sure that no air bubbles form inside the pipette when performing the operation.
When the sample is fully absorbed, add 3 drops of diluent (80 μL) to the well.
Interpret the results within 5-10 minutes. After 10 minutes the results are not accurate.
 
Interpretation of the results:
- Positive test: two lines are evident in the reaction field of the cassette (both C and T line).
- Negative test: Only one line is evident in the field (C).
- Invalid test: if no control line (C) appears after the test, the result is considered invalid. It is not possible to take into account the presence or absence of the line (T). In this case, it is possible that the test procedure was not followed correctly or a test was used beyond the expiration date: in this case, repeat the test with another package.
The presence of the line near the letter (C) indicates the control line and indicates the correct execution of the test.
The line (C) is not a reference line and can have a different intensity than the line (T).
 
Test Storage:
Store tests at room temperature (4 ~ 30°C). Do not refrigerate.
Do not store in direct sunlight. The test is valid until the expiry date on the packaging.