Multi-parameter monitor 10 inch touch screen
zoom_out_map
chevron_left chevron_right

Multi-parameter monitor 10 inch touch screen

1,692.31 Tax included

1,387.14 Tax excluded

new_releases Shipping in 7/10 days.
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)
Description

Multiparameter patient monitor with optional printer – 10" touch screen display
Multi-parameter monitor with high-resolution display, durable and compact structure, equipped with a comfortable handle for easy movement.

3-5 channel ECG display, RESP, SpO2, NIBP, PR, 2-TEMP. Arrhythmia and ST segment analysis.

Pacemaker detention, defibrillation and protection from electrosurgical interference.

168 hours of data storage and 4,000 NIBP measurements.

2 USB ports and ethernet port.

Optional built-in printer.

 



Specifications:

Display
TFT LCD: 10" touch screen
Resolution: 1280×800
Waveforms displayed: Up to 7

ECG
Leads: 5 leads and 3 leads selectable
Display Sensitivity: Auto x 0.125, x 0.25, x 0.5, x 1, x 2, x 4
Scan speed: 6.25, 12.5, 25, 50 mm/s
Heart Rate Range: (HR) 20~300 bpm
Resolution: 1 bpm
Accuracy: ±2 bpm or 2%
CMRR: Diagnosis mode > 95 dB; Monitoring mode > 105 dB; Surgical mode > 105 dB
ST segment monitoring: Measurement range: -2.0 mV ~ 2.0 mV; Alarm Range: -2.0mV~2.0mV

RESP
Method: Trans-thoracic impedance
Bandwidth: 0.1 Hz ~ 3 Hz
RR Measurement Range: Adult 0~120 rpm; Pediatric/Neonatal 0~150 rpm
Accuracy: 6-150 rpm: ±2 rpm or 2% 0-6 rpm: not specified
Apnea alarm threshold: 10, 15, 20, 25, 30, 35, 40 s

SpO2
Measurement and alarm range: 0~100%
Resolution: ≤ 1%
Accuracy: ±2% (70~100%, Adult, Pediatric) ±3% (70~100%, Neonatal)
Perfusion index range: 0.1-20%
PI Resolution: 0.1-9.99%: 0.01% 10-20%: 0.1%
Pulse measurement: 25~240 bpm
Resolution: 1 bpm

NIBP
Method: Oscillometric
Operation: Manual/Automatic/Continuous
AUTOMATIC Measurement Range: Adjustable (2.5-120 min)
Measuring unit: mmHg/kPa
Type of measurement: Systolic, Diastolic, Medium
Resolution: 1 mmHg
Accuracy Max error of ± 5 mmHg
Max standard deviation: 8 mmHg
NIBP pulse measurement range: 20~300 bpm
Resolution: 1 bpm

Temperature (2 channels, 1 probe supplied)
Measurement/Alarm Range: 15~50°C
Resolution: 0.1°C
Accuracy: ±0.2°C (with probe error included)

PRINTER (OPTIONAL)
Thermal Paper: 48 mm
Print speed: 12, 25, 50 mm/s
Number of tracks 3

Feeding
Power outlet: 100~240V AC, 1.4A, 50/60Hz
Rechargeable lithium battery: 2,600 mAh

Dimensions L:27,8 x D:12 x H:18,9 cm
Weight 3.5 kg

Supplied Accessories
Code LTR382 1 x 5-way ECG clip-on cable against discharges (not shown)
– 1 ECG electrode kit, adult, disposable (not shown)
Code LTR384 Finger SpO2 sensor, adult, reusable (not shown)
Code LTR387 NIBP cuff, Adults, reusable (not shown)
– NIBP tube (not shown)
Code LTR385 Skin temperature probe, reusable (not illustrated)
– Power supply (EUR standard) (not shown)
– Ground cable (not shown)
– Rechargeable lithium battery (2600 mAh) (not shown)

Languages available on request
Italian, English, Spanish

Data sheet
MORETTI
MNLTD361
New