Multiparameter patient monitor with optional printer, 10.1″ display

Price: €1,728.00
Tax included



Durable and compact structure, large high-resolution LCD-TFT color display. Handle for easy movement. ECG, RESP, SpO2, NIBP, PR, 2-TEMP. Indicated for use on adults and neonatal. Arrhythmia analysis. Pacemaker detention, defibrillation and protection from electrosurgical interference. 96 hours of memory of all values, 500 NIBP measurements and 60 alarm events. USB port. Optional built-in printer.




Availability Shipping in 7/10 days.
Noleggialo a €40.75 + IVA / mese per 60 mesi con Maggiori informazioni ›
Code MNLTD340 Brand MORETTI



Durable, compact structure, large high-resolution LCD-TFT color display. Handle for easy transport. Display of ECG, RESP, SpO2, NIBP, PR, 2-TEMP. Suitable for adult and neonatal use. Arrhythmia analysis. Pacemaker detection, defibrillation and protection against electrosurgical interference. 96 hours of memory for all values, 500 NIBP measurements and 60 alarm events. USB port. Optional integrated printer.





Accessories in EQUIPMENT





- 1-lead ECG cable with 5 leads, anti-defibrillation clips, IEC, 3.5 m, reusable


- 30 ECG electrodes, adult, disposable


- 1 SPO2 finger sensor, adult, 2.5 m, reusable


- 1 NIBP cuff, Adults, 25cm-35cm, reusable


- 1 NIBP tube, 3m


- 1 Temperature Probe Skin, adult, 3m, reusable


- 1 Power supply (European standard)


- 1 Rechargeable lithium battery (14.8V, 2100mAh)


- 1 Ground cable









Languages available upon request


- Italian


- English


- Spanish


- French


- Portuguese


- German


- Polish


- Chinese


- Turkish



Technical specifications




Display





Color TFT LCD: 10.1”


Resolution: 800x480





Displayed traces: up to 8


Displayed waveforms: up to 11


Oscillation: 6.25, 12.5, 25, 50 mm/s


ECG


Leads: 5 Leads and 3 selectable leads


Display sensitivity: Auto x 0125, x 0.25, x 0.5, x 1, x 2, x 4


Scan speed: 6.25, 12.5, 25, 50 mm/s


Heart rate (HR) range:


Adults 15~300 bpm


Pediatric/Neonatal 15~350 bpm


Resolution: 1 bpm


Accuracy: ±1 bpm or 1%


Filter: Diagnosis mode 0.05 - 150 Hz / Monitoring mode 0.5 - 40 Hz / Surgical mode 1 - 20 Hz


Diagnostic mode 0.05 ~150 Hz


Monitoring mode 0.5~40 Hz


Surgical mode 1~20 Hz


Monitoring segment:


Measurement range -2.0 mV ~ 2.0 mV


Alarm range -2.0 mV ~ 2.0 mV


RESP



Method: transthoracic impedance


Operation: automatic/manual


RR measurement range:


Adults 0 ~150 rpm


Pediatric/Neonatal 0~150 bpm


Resolution: 1 rpm


Apnea alarm threshold:


10, 15, 20, 25, 30, 35, 40 s


Bandwidth: 0.2 - 2.5 Hz (-3 dB)


Scan speed: 6.25, 12.5, 25, 50 mm/s


SpO2


Measurement and alarm range: 0~100%


Resolution: 1%


Accuracy:


±2% (70~100%, Adults, Pediatric)


±3% (70~100%, Neonatal)


Pulse measurement: 25~300 bpm


Resolution: 1 bpm


Update frequency: 1 second


NIBP


Method: Automatic oscillometric


Operation: Manual/Automatic/Continuous


Measurement range in automatic mode:


1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes


Unit of measurement: mmHg/kPa


Measurement type: Systolic, Diastolic, Mean


Pressure range:


- Adults


Systolic 40~270 mmHg


Diastolic 10~215 mmHg


Mean 20~235 mmHg


- Pediatric


Systolic 40~200 mmHg


Diastolic 10~150 mmHg


Mean 20~165 mmHg


-
Neonatal


Systolic 40~135 mmHg


Diastolic 10~100 mmHg


Average 20~110 mmHg


Resolution: 1 mmHg


Accuracy: Maximum mean error ± 5 mmHg


Max. standard deviation: 8 mmHg


Pulse measurement range from NIBP: 40~240 bpm


Resolution: 1 bpm


Accuracy: 3 bpm or 3.5 %


Temperature (2 channels, 1 probe included)


Measurement/alarm range: 0~50°C


Resolution: 0.1°C


Accuracy: ±±0.1°C (without probe)


Channel: 2


Printer (Optional)


Print speed: 25, 50 mm/s


Power supply


Power outlet: 100~240 V AC, 50/60 Hz


Rechargeable lithium battery: 14.8 V








Dimensions W:32 x D:15 x H:26.5 cm





Weight 5 kg

Manufacturer’s features

Accessories in Equipment
- Code LTR303 - 1 ECG cable with 5 leads, defibrillation-proof clip, IEC, 3.5 m, reusable (not illustrated)
- Power supply (standard EUR) (not illustrated)
- Rechargeable lithium battery (14.8V, 2100mAh) (not illustrated)
- Code LDR200 Reusable adult finger SpO2 sensor, 2.5m (not illustrated)
- Code LDR334 Adapter cable for LDR200 (not illustrated)
- Code LDR343 NIBP cuff, Adult, 25cm-35cm, reusable (not illustrated)
- Ground cable (not illustrated)
- 30 electrodes for ECG, adult, disposable (not illustrated)
- Code LDR340 - NIBP tube, 3m (not illustrated)
- Code.
LDR336 - Skin temperature probe, adult, 3m, reusable (not illustrated)

Technical specifications

Technical specifications

Display
Color TFT LCD: 10.1”
Resolution: 800×480
Displayed traces: up to 8
Displayed waveforms: up to 11
Oscillation: 6.25, 12.5, 25, 50 mm/s

ECG

Leads: 5 Leads and 3 selectable leads
Display sensitivity: Auto x 0125, x 0.25, x 0.5, x 1, x 2, x 4
Scan speed: 6.25, 12.5, 25, 50 mm/s
Heart rate (HR) range:
Adults 15~300 bpm
Pediatric/Neonatal 15~350 bpm
Resolution: 1 bpm
Accuracy: ±1 bpm or 1%
Filter: Diagnosis mode 0.05 - 150 Hz; Monitoring mode 0.5 - 40 Hz; Surgical mode 1 - 20 Hz
Diagnostic mode 0.05 ~150 Hz; Monitoring mode 0.5~40 Hz; Surgical mode 1~20 Hz
Monitoring segment: Measurement range -2.0 mV ~ 2.0 mV; Alarm range -2.0 mV ~ 2.0 mV

RESP
Method: transthoracic impedance
Operation: automatic/manual
RR measurement range:
Adults 0 ~150 rpm
Pediatric/Neonatal 0~150 bpm
Resolution: 1 rpm
Apnea alarm threshold: 10, 15, 20, 25, 30, 35, 40 s
Bandwidth: 0.2 - 2.5 Hz (-3 dB)
Scan speed: 6.25, 12.5, 25, 50 mm/s

SpO2
Measurement and alarm range: 0~100%
Resolution: 1%
Accuracy:
±2% (70~100%, Adults, Pediatric)
±3% (70~100%, Neonatal)
Pulse measurement: 25~300 bpm
Resolution: 1 bpm
Update frequency: 1 second

NIBP
Method: Automatic oscillometric
Operation: Manual/Automatic/Continuous
Measurement range in automatic mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Unit of measurement: mmHg/kPa
Measurement type: Systolic, Diastolic, Mean
Pressure range:
- Adults
Systolic 40~270 mmHg
Diastolic 10~215 mmHg
Mean 20~235 mmHg
- Pediatric
Systolic 40~200 mmHg
Diastolic 10~150 mmHg
Mean 20~165 mmHg
- Neonatal

Systolic 40~135 mmHg
Diastolic 10~100 mmHg
Average 20~110 mmHg
Resolution: 1 mmHg
Accuracy: Maximum mean error ± 5 mmHg
Max. standard deviation: 8 mmHg
Pulse measurement range from NIBP: 40~240 bpm
Resolution: 1 bpm
Accuracy: 3 bpm or 3.5 %
Temperature (2 channels, 1 probe included)
Measurement/alarm range: 0~50°C
Resolution: 0.1°C
Accuracy: ±±0.1°C (without probe)
Channel: 2

Printer (Optional)
Print speed: 25, 50 mm/s

Power supply
Power outlet: 100~240 V AC, 50/60 Hz
Rechargeable lithium battery: 14.8 V


Dimensions W:32 x D:15 x H:26.5 cm

Weight 5 kg

Optional accessories available

  • Code LDR350 - Monitor cart plate  (not illustrated)
  • Code CO156 - Cable-support arm for trolley CO150 (not illustrated

Schema dimensionale del produttore Code CO150 - Aluminum trolley Schema dimensionale del produttore Code CO159 - Wall mount Schema dimensionale del produttore Code LDR330N - Optional printer Schema dimensionale del produttore Code LTD826 - Patient care data management Viewer software Schema dimensionale del produttore Code LDR329 - Central monitoring software system. LAN connection. Multi-display mode on dual or single display. Large storage capacity for both waveforms and numerical measurements. Web display.
Experiences with this product

Reviews

—0 Reviews
5 00
4 00
3 00
2 00
1 00

Product reviews are shared across our shops. We check submissions before publication. Verified purchase means we could link the review to an actual order.

No reviews match these filters yet.