K12 12" MULTIPARAMETER MONITOR
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows the complete analysis of the patient's physiological condition.
- Ergonomic design with intuitive user interface
- USB socket for data transfer and software update
- 9 tracks on on-screen waveforms
- Windows-based display, easy to manage
- visual and audible alarm for physiological and technical abnormalities
- Large memory capacity
- Suitable for use with genuine Nellcor sensors
- protection against defibrillator discharges, resistance against interference from electrosurgical units; Detection and inhibition of cardiac pacemaker pulses
Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.
PC software GB only.
360° visible indicator with 3-level alarm.
Lithium battery, up to 2.5 hours of continuous monitoring.
1 pc.
ECG
- Input dynamic range: ±(0.5~5 mVp)
- Input differential impedance: =10 MO
- Bandwidth:
- 0.05~150 Hz (Diagnostic)
- 0.5~40 Hz (Monitoring)
- 1~20 Hz (Operation)
- CMRR:
- =90 dB (Diagnostics)
- =105 dB (Monitoring & Operation)
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
- Pacemaker pulse detection and inhibition function
RESP
- Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
- Measuring range: 21.0~50.0 °C ±0.2 °C between 25~45 °C
NIBP
- Technique: Oscillometric method
- Typical measurement time: - NIBP SYS measuring range:
- 40~275 mmHg (Adults)
- 40~200 mmHg (Pediatric)
- 40~135 mmHg (Infants)
- NIBP DIA measuring range:
- 10~210 mmHg (Adults)
- 10~150 mmHg (Pediatric)
- 10~95 mmHg (Infants)
NIBP MAP measuring range:
- 20~230 mmHg (Adults)
- 20~165 mmHg (Pediatric)
- 20~110 mmHg (Infants)
- NIBP Measurement Accuracy:
- Average difference: ±5 mmHg
- Standard deviation: 8 mmHg
- Measurement mode NIBP: Manual, Auto, STAT, Multicycle
- Self-measurement intervals: 1-480 min
SpO2
- Technique: Dual wavelength optical method
- Measuring range: 0%~100% ±2% for SpO2 range 70~100%
- PR Measurement Range: 30~250bpm ±2bpm or ±2%, whichever is greater
- Low perfusion yield: Up to 0.3%.
CO2
- Technique: Infrared optical method
- Sampling mode: Sidestream or Mainstream
- Measuring range: 0~150 mmHg
- Measurement accuracy:
- 0~40 mmHg ±2 mmHg
- 41~70 mmHg ±5% of reading
- 71~100 mmHg ±8% of reading
- 101~150 mmHg ±10% of reading
- Flow rate: 50 ml/min ±10 ml/min (Sidestream)
Other characteristics
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA
- Built-in lithium battery: 11.1V/4400mAh
- Screen: 12 inch TFT screen
- Alarm method: 3-level sound-visual alarm
- Network: Ethernet
- Safety standard: IEC 60601-1
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cord
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES, PL, RU