RespSense Capnograph (EtCO2)
zoom_out_map
chevron_left chevron_right

RespSense Capnograph (EtCO2)

The RespSense WIDESCREEN touch-screen monitor uses MedAir sidestream technology for a wide range of clinical uses for both intubated and non-intubated patients.

Portable, accurate, and affordable, RespSense is perfect for sleep labs, procedural sedation, and clinical uses, where quick and easy EtCO2 measurement is needed.

- WIDESCREEN touch-screen
- Numerical display of EtCO2 and respiratory rate parameters
- EtCO2 MedAir technology
- 1.5-hour waveform display of...

€2,433.60 Tax included

€2,317.71 Tax excluded

Shipping in 15 days.
local_shipping Shipping in 15 days.
Secure payments
by credit card, Paypal and bank transfer.
Fast shipping
with Poste, DPD, FedEx, DHL and UPS couriers
Customer service
via Whatsapp + 39.371.43.61.201
Description

The RespSense WIDESCREEN touch-screen monitor uses MedAir sidestream technology for a wide range of clinical uses for both intubated and non-intubated patients.

Portable, accurate, and affordable, RespSense is perfect for sleep labs, procedural sedation, and clinical uses, where quick and easy EtCO2 measurement is needed.

- WIDESCREEN touch-screen
- Numerical display of EtCO2 and respiratory rate parameters
- EtCO2 MedAir technology
- 1.5-hour waveform display of EtCO2 and respiratory rate
- Backlit LCD display
- Visual and audible alarms
- Data output via RS-232 port



Specifications:

- Dimensions: 200x135x50 mm
- Weight: 800 g

Feeding
- Power supply: 100-240 VAC, 50-60 Hz
- Power consumption: 3.6 W with batteries, 9 W with mains power
- Input: 12VDC, 720mA

Utilization
- Temperature: 0°C to 40°C
- Humidity: 10-90% (non-condensing)
- Atmospheric pressure: 645-795 mmHg (860-1060 hPa)

Preservation
- Temperature: -20°C to 50°C
- Humidity: 10-90% (non-condensing)
- Atmospheric pressure: up to 4 atmospheres

Pump
- Pump flow: 75 ml/min
- Flow accuracy: -15/15 ml/min

Battery
- Type: Internal rechargeable Lithium battery
- Capacity: about 8 hours
- Charging time: approx. 17 hours or 2 hours for every hour of use

Capnography
- Breathing range: 3-80 breaths/min
- Update rate: 1 time for each breath
- Breathing accuracy: 3-50 breaths/min -2/2, 51-80 breaths/min -5/5
- EtCO2/CO2 range: 0-99 mmHg or 0-9.9 kPa
- EtCO2/CO2 accuracy: -0.2/0.2 kPa, -2/2 mmHg, +6% of reading (EtCO2/CO2 reading reaches stability after 10 minutes of power-on)



Equipment:

- RespSense Capnograph
- 3 Replacement filters
- 3 Nasal CO2 Monitoring Cannulas for Adults
- 1 CO2 sampling line
- 1 x Straight T-connector
- 1 Sens PS-NA
- 1 Battery charger

Data sheet
PALS1R-9R
New