Description
It allows you to detect saturation, heartbeat and perfusion from the patient's finger (finger 8-16 mm) in a hospital or outpatient setting.
Key features:
- SpO2 and pulse detection
- Pulse histogram
- calculation of perfusion index. The perfusion index is a numerical value that indicates the intensity of the pulse at the point where the sensor is placed. It is a relative value that varies from patient to patient and depending on the area in which the sensor is placed
- great precision and repeatability of the results: the devices are produced by Gima (in factories in R.P.C.) under strict quality controls guaranteed by an Italian certification body (CE 0476 CERMET)
- Accuracy from the first reading in seconds thanks to a
a unique noise filter system - great stability during measurement (finger bending, Parkinson's disease, hand movements, button pressing)
- visual and acoustic alarms
- automatic switching on and off (if the finger is not inserted)
- Low charge indicator
- Manual in 9 languages (GB, FR, IT, ES, DE, GR, PT, PL, AR)
- 50 hours of operation with full batteries
- Supplied in a plastic case with batteries and case
Specifications:
-Pulsations:
- Range: 30-240 bpm
- Accuracy: ± 2 bpm (2%)
- Resolution: 1bpm
- SpO2:
- Field: 35%-99%
- Accuracy: ± 2% (75-99%)/± 3% (50-75%)
- Resolution: 1%
- Perfusion index:
- Range: 0-20%
- Accuracy: ± 0.1% (0.2-2%)/± 0.2% (2-10%)
- Resolution: 0.1%
- Alarm: SpO2: Lower limit 90%
- Pulse alarm: low: 120 bpm
- Power supply: 1.5V (AAA) alkaline batteries x 2
- Standards: IEC 60601-1-2 Class II
- LCD display: oxygen saturation, beat, battery level indication
- Size: 6.6 x 3.6 x 3.3 cm
- Weight: 60 g including batteries
- Italian production (made in P.R.C.)
- BD/RDM: 237641
- NDT: Z1203020408
- Paraf: 903112389
- EAN13: 8023279342659
- GMDN: 17148
Key features:
- SpO2 and pulse detection
- Pulse histogram
- calculation of perfusion index. The perfusion index is a numerical value that indicates the intensity of the pulse at the point where the sensor is placed. It is a relative value that varies from patient to patient and depending on the area in which the sensor is placed
- great precision and repeatability of the results: the devices are produced by Gima (in factories in R.P.C.) under strict quality controls guaranteed by an Italian certification body (CE 0476 CERMET)
- Accuracy from the first reading in seconds thanks to a
a unique noise filter system - great stability during measurement (finger bending, Parkinson's disease, hand movements, button pressing)
- visual and acoustic alarms
- automatic switching on and off (if the finger is not inserted)
- Low charge indicator
- Manual in 9 languages (GB, FR, IT, ES, DE, GR, PT, PL, AR)
- 50 hours of operation with full batteries
- Supplied in a plastic case with batteries and case
Specifications:
-Pulsations:
- Range: 30-240 bpm
- Accuracy: ± 2 bpm (2%)
- Resolution: 1bpm
- SpO2:
- Field: 35%-99%
- Accuracy: ± 2% (75-99%)/± 3% (50-75%)
- Resolution: 1%
- Perfusion index:
- Range: 0-20%
- Accuracy: ± 0.1% (0.2-2%)/± 0.2% (2-10%)
- Resolution: 0.1%
- Alarm: SpO2: Lower limit 90%
- Pulse alarm: low: 120 bpm
- Power supply: 1.5V (AAA) alkaline batteries x 2
- Standards: IEC 60601-1-2 Class II
- LCD display: oxygen saturation, beat, battery level indication
- Size: 6.6 x 3.6 x 3.3 cm
- Weight: 60 g including batteries
- Italian production (made in P.R.C.)
- BD/RDM: 237641
- NDT: Z1203020408
- Paraf: 903112389
- EAN13: 8023279342659
- GMDN: 17148