by credit card, Paypal and bank transfer.
with BRT, DPD and FedEx couriers
via Whatsapp + 39.371.43.61.201
Durable and compact structure, large high-resolution LCD-TFT color display. Handle for easy movement. ECG, RESP, SpO2, NIBP, PR, 2-TEMP. Indicated for use on adults and neonatal. Arrhythmia analysis. Pacemaker detention, defibrillation and protection from electrosurgical interference. 96 hours of memory of all values, 500 NIBP measurements and 60 alarm events. USB port. Optional built-in printer.
Accessories SUPPLIED
- 1 5-way ECG cable with anti-defibrillation clip, IEC, 3.5m, reusable
- 30 ECG Electrodes, Adult, Disposable
- 1 SPO2 finger sensor, adult, 2.5m, reusable
- 1 NIBP Cuff, Adult, 25cm-35cm, Reusable
- 1 NIBP tube, 3m
- 1 Temperature Probe Skin, adult, 3m, reusable
- 1 Power supply (EUR standard)
- 1 Rechargeable lithium battery (14.8V, 2100mAh)
- 1 Ground cable
Languages available on request
- English
- English
- Spanish
- French
- Portuguese
- German
- Polish
- Chinese
-Turkish
Specifications
Display
TFT color LCD: 10.1"
Resolution: 800x480
Tracks displayed: up to 8
Waveforms displayed: Up to 11
Oscillation: 6.25, 12.5, 25, 50 mm/s
ECG
Leads: 5 leads and 3 leads selectable
Display Sensitivity: Auto x 0.125, x 0.25, x 0.5, x 1, x 2, x 4
Scan speed: 6.25, 12.5, 25, 50 mm/s
Heartbeat (HR) range:
Adults 15~300 bpm
Pediatric/Neonatal 15~350 bpm
Resolution: 1 bpm
Accuracy: ±1 bpm or 1%
Filter: Diagnosis mode 0.05 - 150 Hz / Monitoring mode 0.5 - 40 Hz / Surgical mode 1 - 20 Hz
Diagnosis mode 0.05 ~150 Hz
Monitoring Mode 0.5~40 Hz
Surgical mode 1~20 Hz
Segment Tracking:
Measuring range -2.0 mV ~ 2.0 mV
Alarm range -2.0 mV ~ 2.0 mV
RESP
Method: trans-thoracic impedance
Operation: Auto/Manual
RR Measurement Range:
Adults 0 ~150 rpm
Pediatric/Neonatal 0~150 bpm
Resolution: 1 rpm
Apnea alarm threshold:
10, 15, 20, 25, 30, 35, 40 s
Bandwidth: 0.2 - 2.5 Hz (-3 dB)
Scan speed: 6.25, 12.5, 25, 50 mm/s
SpO2
Measurement and alarm range: 0~100%
Resolution: 1%
Precision:
±2% (70~100%, Adult, Pediatric)
±3% (70~100%, Neonatal)
Pulse measurement: 25~300 bpm
Resolution: 1 bpm
Refresh Rate: 1 second
NIBP
Method: Automatic Oscillometric
Operation: Manual/Automatic/Continuous
Measurement range in automatic mode:
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Measuring unit: mmHg/kPa
Type of measurement: Systolic, Diastolic, Medium
Pressure range:
-Adults
Systolic 40~270 mmHg
Diastolic 10~215 mmHg
Average 20~235 mmHg
-Pediatric
Systolic 40~200 mmHg
Diastolic 10~150 mmHg
Average 20~165 mmHg
- Neonatal
Systolic 40~135 mmHg
Diastolic 10~100 mmHg
Average 20~110 mmHg
Resolution: 1 mmHg
Accuracy: Max error of average ± 5 mmHg
Max standard deviation: 8 mmHg
NIBP pulse measurement range: 40~240 bpm
Resolution: 1 bpm
Accuracy: 3 bpm or 3.5 %
Temperature (2 channels, 1 probe supplied)
Measurement/alarm range: 0~50°C
Resolution: 0.1°C
Accuracy: ±0.1°C (without probe)
Channel: 2
Printer (Optional)
Print speed: 25, 50 mm/s
Feeding
Power Outlet: 100~240V AC, 50/60Hz
Rechargeable lithium battery: 14.8V
Dimensions L:32 x D:15 x H:26.5 cm
Weight 5 kg