The MAGUS Pol 850 polarizing microscope is designed to operate in transmitted and reflected light. Available search methods: polarization and brightfield. The microscope is used to study anibiological, geological, and anisotropic polymer objects, as well as matte glossy sections up to 15 mm thick with a glossy side. The microscope is perfect for a wide range of tasks of professionals in the fields of medicine, forensics, mineralogy, crystallography or petrography.
Optical
The optics of the microscope are infinitely correct and are free of internal tensions. The image formed by the lens is authentic, glare-free, high-contrast and detailed. The lens is installed in a nosepiece with grooves centered on the optical axis. There are five grooves, with four objectives included in the kit you can install an additional objective lens to achieve additional magnification within the microscope's magnification range. The objectives are designed to work with specimens without coverslips.
The trinocular head allows you to install a digital camera (not included) in the trinocular tube. The beam split is 100:0 or 0:100, meaning all the light goes to the camera or eyepiece tubes. The left eyepiece tube is equipped with a diopter adjustment ring: it is rotated to compensate for the difference in vision between the eyes and to obtain the clearest possible image of the sample.
Lighting
30 W halogen lamps are used for transmitted and reflected light. Their brightness is sufficient to obtain a clearly readable image on each lens, and the "warm" emission spectrum is comfortable during long-term use. The Köhler lighting setting will provide higher resolution and remove artifacts in the field of view and darkening at the edges. Light filters are used to fine-tune color reproduction when working in reflected light.
Polarization is available for both transmitted and reflected light. To begin observations in polarized light, an analyzer is introduced into the optical path. Subsequently, the relative position of the analyzer and polarizer is changed by rotating them, which also changes the polarization angle. The contrast of the objects is increased with the help of compensators installed in a special housing in the intermediate tube. The same mount also contains a Bertrand lens that is used for conoscopic examinations.
Stage and focusing mechanism
The microscope has a rotatable table: rotating it changes the way the sample refracts light in the presence of polarized light. The stage is equipped with a scale on which the angle of rotation can be determined with an accuracy of up to 0.1°. To obtain the brightest and clearest image, the stage can be centered relative to the optical axis of the microscope.
The coarse and fine focus knobs are located at the bottom of the mount, so the user can assume a relaxed pose with their hands on the table. The coarse tension can be adjusted and there is also a coarse focus lock. The fine focus ensures smooth movement of the sample.
Fixings
To get the most out of the microscope, use accessories from the MAGUS line: objective eyepieces, calibration slides, digital cameras, etc.
Key features:
- For working in transmitted, polarized, reflected, and natural light conditions
- Trinocular head with tube for digital camera Beam split of 100:0 or 0:100
- Tension-free planachromatic lenses for sharp images free of artifacts and false internal reflections
- Halogen illumination of the work area, a comfortable colour spectrum for the eyes Lamp power 30 W
- Rotary stage, polarizer and analyzer with rotation angle markings, Bertrand lens and compensators
- The revolver grooves and stage are centered relative to the optical axis of the microscope
- Compatible with additional accessories
The package contains:
- Base with power input, transmitted light source and condenser, focusing mechanism, stage and nosepiece
- Illuminator for observations in reflected light with bulb housing
- Trinocular head
- Bertrand lens intertube, analyzer and compensator housing
- Compensators: λ Compensator, λ/4 Compensator, Quartz Wedge
- Planachromatic Infinity Lens: PL 5x/0.12 WD 26.1 mm
- Planachromatic Infinity Lens: PL 10x/0.25 WD 5.0mm
- Planachromatic Infinity Lens: PL 40x/0.6 (with spring mechanism) WD 3.98 mm
- Planachromatic Infinity Lens: PL 60x/0.7 (with spring mechanism) WD 2.03 mm
- Eyepiece 10x/20 mm (2 pcs.)
- 10x/20 mm eyepiece with graduated scale. Scale value: 0.1 mm
- 1x C-mount adapter
- Allen key
- Power cord
- Dust cover
- User Manual & Warranty Card
Available on request:
- Eyepiece 16x/11 mm (2 pcs.)
- Eyepiece 20x/11 mm (2 pcs.)
- Planachromatic objective lens at infinity: PL 2.5x/0.07 WD 11 mm
- Planachromatic Infinity Lens: PL 50x/0.7 (with spring mechanism) WD 3.67 mm
- Planachromatic Infinity Lens: PL 80x/0.8 (with spring mechanism) WD 1.25 mm
- Planachromatic Infinity Objective: PL 100x/0.85 (with spring mechanism) WD 0.4 mm
- Mechanical stage
- Digital camera
- Calibration slide
Brand | MAGUS |
Guarantee | 5 years |
EAN | 5905555018539 |
Package size (LxWxH) | 44x42x67 cm |
Shipping Weight | 11.5 kg |
Type | Biological, Light/Optical |
Head | Trinocular |
Seat tube | Siedentopf |
Cylinder head tilt angle | 30° |
Magnification, x | 50 — 600 |
Magnification range | 200x to 800x |
Magnification, x (optional) | 25–1000/1600/2000 |
Eyepiece tube diameter, mm | 23.2 |
Eyepieces | 10х/20 10x/20 with graduated scale (*optional: 16x/11 20х/11) |
Objectives | infinitely planachromatic, non-deforming: PL 5x/0.12 PL 10x/0.25 PL 40x/0.6 PL 60x/0.7 (*optional: PL 2.5x/0.07 PL 50x/0.7 PL 80x/0.8 PL 100x/0.85) Parfocal height of 45 mm, designed for the study of specimens without coverslips |
Nosepiece Revolver | for 5 lenses, centering |
Working distance, mm | 26.1 (5x) 5.0 (10x) 3.98 (40x) 2.03 (60x) 11 (2.5x) 3.67 (50x) 1.25 (80x) 0.4 (100x) |
Coffee table, mm | Ø150 |
Coffee table features | 360° rotatable, centering, 1° gradation of the angle of rotation A Vernier scale for measuring angles with an accuracy of 0.1° |
Eyepiece diopter adjustment, diopters | ±5 (on left barrel) |
Capacitor | Abbe NA 1.25 condenser with an adjustable aperture diaphragm and rotatable lenses |
Diaphragm | adjustable aperture diaphragm, field diaphragm with adjustable iris |
Fire | Coaxial, coarse focus (21 mm, 39.8 mm/rev, with fixing knob and micrometer screw tension adjustment knob) and fine focus (0.002 mm micrometer screw) |
Lighting | Halogen |
Adjusting the brightness | Yes |
Feeding | 220±22 V, 50 Hz, AC mains |
Light source type | reflected and transmitted light: 12 V/30 W |
Optical filters | reflected light: opaque, yellow, green, blue |
Operating Temperature Range, °C | 5 — 35 |
User level | Experienced users, professionals |
Assembly and installation difficulty level | complicated |
Polarizer | Transmitted: with 0°, 90°, 180°, 270° marked on the 360° rotatable scale Reflected light: removable |
Intermediate tube | Integrated analyzer rotatable from 0–360° A Vernier scale for measuring angles with an accuracy of 0.1° Bertrand lenses Housings for installing compensators |
Compensator | λ compensator λ/4 quartz wedge compensator |
Application | laboratory/medical |
Lighting position | double |
Research method | brightfield, polarized light |
Set with case/case/bag | Dust cover |