Secure payments
by credit card, Paypal and bank transfer.
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
via Whatsapp + 39.371.43.61.201
Description
A high-quality professional multifunction tool.
DefiMonitor XD combines a compact and reliable design, the highest level of security and easy use.
Range of 8 manual (XD1, XD3, XD10, XD30) or manual + AED defibrillators (XD100, XD300, XD110, XD330) with or without SpO2 and external pacer.
Supplied with adult/pediatric electrodes, disposable adult adhesive pads, a connection cable, an ECG cable, a power cable, 1 gel tube, 1 roll of paper.
Standard software: GB, FR, DE, IT ,ES, KT, PT, RO, TR, CN.
Manual: GB, IT (DE, ES, PT, RU, UA on request).
Other software and manuals available on request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US.
Dimensions: 33 x 29 x 16 cm
1 pc.
Specifications:
Defibrillation
- Pulse: biphasic, current-regulated
- Energy (automatic mode) 140-360 J
- Manual energy levels: 5 J, 10 J, 20 J, 30 J, 50 J, 100 J, 200 J, 300 J, 360 J
- Charging times: - Cardioversion: manual activation, QRS marker
ECG
-Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
- Patient resistance: 23-200 Ohm
- Heart rate: 30-300 par min
Pacer
- Transthoracic pacemaker
- Mode: Fixed, On-Demand, Overdrive
Thermal Printer
- Resolution: 200 dpi
- Feed rate 25 mm/s, 50 mm/s
TFT monitor, LCD-Blue-mode
- 115 x 86 mm (4.7''/120 mm diagonal)
- 320 x 240 pixels
Electrodes
- Adhesive electrodes, surface life 3 years
- Cable length 3.5 m SavePads Connect
Data management
- Removable memory 2 Gb
- Data recording Voice recording > 90 h
Feeding
- Voltage 90-264V, 50-60 Hz
Rechargeable NiCD battery:
- Capacity: 1.4 Ah Voltage: 12 V
- Discharges: 70-200 J
Monitoring: 3 h Charging Time: 2.5 h
Resuscitation guidelines
- AHA/ERC of your choice
Rules
- IEC60601-1:1988 + A1:1991 + A2:1995 (Electrical Safety of Medical Electrical Instruments)
- IEC60601-1-2:2001 (Electromagnetic compatibility)
- IEC60601-1-4:1996 + A10:1999 (Programmable Medical Electrical Systems)
- IEC60601-2-4 :2002 (Defibrillators)
- EN1789:2003 (Ambulance standard)
- Protection type class IP33
DefiMonitor XD combines a compact and reliable design, the highest level of security and easy use.
Range of 8 manual (XD1, XD3, XD10, XD30) or manual + AED defibrillators (XD100, XD300, XD110, XD330) with or without SpO2 and external pacer.
Supplied with adult/pediatric electrodes, disposable adult adhesive pads, a connection cable, an ECG cable, a power cable, 1 gel tube, 1 roll of paper.
Standard software: GB, FR, DE, IT ,ES, KT, PT, RO, TR, CN.
Manual: GB, IT (DE, ES, PT, RU, UA on request).
Other software and manuals available on request: CZ, FI, HU, NL, NO, PL, RU, SE, DK, GR, LT, JU, AE, BR, CN, IR, JP, TH, US.
Dimensions: 33 x 29 x 16 cm
1 pc.
Specifications:
Defibrillation
- Pulse: biphasic, current-regulated
- Energy (automatic mode) 140-360 J
- Manual energy levels: 5 J, 10 J, 20 J, 30 J, 50 J, 100 J, 200 J, 300 J, 360 J
- Charging times: - Cardioversion: manual activation, QRS marker
ECG
-Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
- Patient resistance: 23-200 Ohm
- Heart rate: 30-300 par min
Pacer
- Transthoracic pacemaker
- Mode: Fixed, On-Demand, Overdrive
Thermal Printer
- Resolution: 200 dpi
- Feed rate 25 mm/s, 50 mm/s
TFT monitor, LCD-Blue-mode
- 115 x 86 mm (4.7''/120 mm diagonal)
- 320 x 240 pixels
Electrodes
- Adhesive electrodes, surface life 3 years
- Cable length 3.5 m SavePads Connect
Data management
- Removable memory 2 Gb
- Data recording Voice recording > 90 h
Feeding
- Voltage 90-264V, 50-60 Hz
Rechargeable NiCD battery:
- Capacity: 1.4 Ah Voltage: 12 V
- Discharges: 70-200 J
Monitoring: 3 h Charging Time: 2.5 h
Resuscitation guidelines
- AHA/ERC of your choice
Rules
- IEC60601-1:1988 + A1:1991 + A2:1995 (Electrical Safety of Medical Electrical Instruments)
- IEC60601-1-2:2001 (Electromagnetic compatibility)
- IEC60601-1-4:1996 + A10:1999 (Programmable Medical Electrical Systems)
- IEC60601-2-4 :2002 (Defibrillators)
- EN1789:2003 (Ambulance standard)
- Protection type class IP33
Data sheet
6 other products in the same category: