18 L DENEB 18 Class B autoclave with printer and USB port
zoom_out_map
chevron_left chevron_right

18 L DENEB 18 Class B autoclave with printer and USB port

€1,804.38 VAT included

€1,479.00 VAT excluded

notifications_active Last items in stock
Secure payments
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
Description

- Class B fractional vacuum autoclave
- Quick program (flash)
- Cleaning program
- User programmable
-Lcd
-Automatic
- Adjustable sterilization time
- Supports Bowie & Dick Test, Helix Test, and Vacuum Test
- Can maintain temperature to speed up subsequent sterilization
- USB output for the printer
- Easy room cleaning
- Easy maintenance
- Easy to use
- Protection system against unintentional opening of the door
- Operating temperature: 121° and 134°

Guarantee:
DENEB autoclaves have a 24-month warranty for all customers.

The autoclave is equipped with the following sterilization cycles:
- 121°C - solids - duration 24 minutes
- 121°C - porous bodies - duration 30 minutes
- 121°C - hollow bodies - duration 33 minutes
- 134°C - solids - duration 8 minutes
- 134°C - porous bodies - duration 14 minutes
- 134°C - hollow bodies - duration 17 minutes
- Bowie-Dick test - duration 4 minutes
- Vacuum test - duration 15 minutes

134°C cycles are normally used for the sterilization of solid and ferrous materials. 121°C cycles are used for thermoplastics, textiles, and sensitive materials. Always sterilize the materials according to the instructions given by the device manufacturer.

How to Choose the Sterilizer:
Sterilization cycles are divided into classes based on the type of autoclavable material. The 3 classes are:
- Type B (class B): sterilization of bagged or unwrapped instruments, solids, type A cables (turbines, handpieces and devices with blind or small holes) and type B (cannulas and tubes with considerable passages) and porous products;
- Type S (class S): sterilization of type B hollow instruments (cannulas and tubes with considerable passages), small porous articles and solids wrapped and unbagged.
- Type N (class N): sterilization of solid instruments that are not wrapped

Unwrapped sterilized instruments are intended for immediate use or for storage, transportation, and non-sterile application to prevent cross-infection. It is essential that sterilization and associated equipment are used only for sterilization of the type of load for which they are designed.

The choice of sterilizer, sterilization cycle, or the quality of services provided may be inadequate for a particular load. Consequently, the suitability of a sterilization procedure for a particular product must be verified by validation.

Certification: CE 1023, ISO 13485
Standard: UNI EN 13060:2015 (BS EN 13060:2004 + A2:2010)
Voltage: 220V
Frequency: 50HZ
Consumption: 2.4 KW
Sterilization temperature: 121°C, 134°C

External dimensions: 65 cm (depth) x 50 cm (width) x 43 cm (height)
Chamber diameter: 25 cm
Chamber depth: 35 cm
Chamber volume: 18 liters
Minimum dimensions of the support surface: 54 x 41.5 cm
Net weight: 59 Kg

Display: LCD 6 x 4.25 cm
Languages: Italian and English
Door Lock: Mechanical + Electric Lock
User Password: YES
Printer: YES
USB Output: YES
Max Working Pressure: 0.21 - 0.23 MPa

Pressure Sensor Accuracy: 0.1 KPA
Max working temperature: 134 – 137 °C
Temperature Sensor Accuracy: 0.1 °C

Vacuum pump type: double-head
Number of vacuum pumps: 1
Number of water pumps: 1
Number of clean water tanks: 1
Number of waste water tanks: 1
Tank life: 3-4 sterilizations
Number of steam generators: 1
Number of safety valves: 1
Over-temperature protection system: YES
Overpressure protection system: YES
Antibacterial filters: 1
   
Sterilization Programs:
- 121 °C solids
- 121 °C Porous bodies
- 121 °C hollow bodies
- 134 °C Solids
- 134 °C Porous bodies
- 134 °C hollow bodies
- Bowie & Dick test
- Helix Test
- Vacuum Test
- Cleaning program
- Prions
- User programmable

Working conditions:
- Ambient temperature: 5 °C - 40 °C
- Relative humidity: ≤80%
- Atmospheric pressure: > 70 kPa
- Voltage: 230VAC, 50Hz, 2500VA
- Maximum working pressure: 0.21 - 0.23 MPa
- Maximum operating temperature: 134 - 137 °C

Right of withdrawal
For this product, the right of withdrawal within 10 days of purchase is also extended to customers with a VAT number.

Technical Assistance
RAM Apparecchi Medicali srl is a technical assistance center, so in the event of problems and/or failures both within the warranty period and outside it you can refer directly to us by calling the toll-free number 800.777.534. 
In the event of failures within the warranty period, we will collect the product from you with the Bartolini courier within 48 hours of the report, repair and/or replace it, and return it to you as soon as possible (all at our expense).

Data sheet
AnteaMed
ST3PV-18L-E
New
0635346797569