AUTOSENSE VOICE Talking Blood Glucose Meter for the blind, for blood glucose monitoring
by credit card, Paypal and bank transfer.
with BRT, DPD and FedEx couriers
via Whatsapp + 39.371.43.61.201
AUTOSENSE VOICE Talking Blood Glucose Meter for the blind.
Simple talking glucometer that allows blind (blind), and visually impaired people, without entering the code, to independently measure blood glucose and keep blood sugar under control.
CAUTION : The meter must use test strips code GLM35 ( 25 strips ) or GLM36 ( 50 strips ) for operation. When purchasing the tool, remember to add strips.
Talking Glucose Meter AutoSense Voice, the new blood glucose meter! … it is the evolution of the previous one, the Senso Lite Nova Plus, and is designed to make it easier for everyone, especially the visually impaired or those with visual impairment, since it does not require the insertion of a code before use, which makes measurements easier and faster and eliminates errors associated with incorrectly coded meters.
AutoSense Voice enables simple, accurate and fast blood glucose level measurements and offers hygienic operation and the broadest and most intuitive functionality available in a blood glucose meter.
The speaking function of AutoSense Voice makes it usable in full autonomy by, in particular, the visually impaired and the blind. Clear and simple sentences spoken in a female voice guide users through the measurement steps and allow them to listen to the detected results.
Features and functions:
- Biosensor technology with automatic coding.
- Ergonomic and compact design.
- Easy and hygienic operation.
- Excellent accuracy and fast results (average 5 seconds).
- Small blood sample (0.5 μl) and AST function to reduce pain.
- Large memory capacity (last 500 test data) with averaging function.
- Optional whole blood calibration or equivalent plasma calibration.
- Optional speaking function in AutoSense Voice.
- Wide range of user-friendly features.
- ISO 15197:2013 compatibility.
Speaking Function:
This feature is available in AutoSense Voice. When the speaking function of AutoSense Voice is enabled, instructions and important values displayed on the screen are vocalized. This is a great help for people who may have trouble reading the characters displayed on the screen. Thus, the risk of misuse or misreading due to poor vision can be significantly reduced.
Autocoding system:
The AutoSense Voice meter is equipped with an autocoding system to ensure that the meter and strips are working properly
together. Therefore there is no need for manual coding of the meter. Inserting the test strip will automatically turn on the meter.
Small sample volume:
Only a small drop of blood (0.5 μl) is required for an accurate measurement, which makes the test virtually painless.
Fast test results:
The results can be read on the large LCD display in just 5 seconds.
Two units of measurement, optional calibration:
The AutoSense Voice tool can display results using 2 different units of measurement: mmol/lo mg/dl. One mmol/l is equivalent to about 18 mg/dl. Meter calibration is also optional: both whole blood and plasma equivalent calibration are available.
Large memory capacity, average computing:
AutoSense Voice can store the last 500 test results (including dates and times) and can also calculate 7-, 14-, 30-, 60-, and 90-day averages. The calculated average includes all test results from the selected period, except for those that are flagged.
Strip Ejection:
To avoid contact with blood, used strips can be disposed of easily using the strip eject button. This makes the handling of strips much easier and more hygienic.
Special flags:
You can set pre-meal, post-meal, and sports activity indicators for each measurement result to make the measurement process more accurate. In addition, the results of fake or control measurements can be marked in such a way that they cannot be used to calculate average glucose levels.
Alternative site testing:
The alternate site blood collection feature can be used when blood samples are collected from sites other than fingertips (palms, forearms, and upper arms) to ensure less pain during collection.
Alarm function:
The user can set three daily alarms to act as a test reminder.
- Type: Advanced biosensor technology with automatic coding.
- Sample: min. 0.5 μl of capillary whole blood.
Operating Range:
- Temperature: 10 - 40 °C.
- relative humidity: - altitude: below 3000 m.
- hematocrit: 30-55%.
- Measuring range: 20 - 600 mg/dl (1.1-33.3 mmol/l).
- Average test time: 5 seconds.
- Storage capacity: Last 500 test data with time and date.
- Speaking function: female voice.
- Automatic switch-on: when the test strip is inserted.
- Auto Power Off: Within 2 minutes of the last button being activated.
- Warning and error signals: out of measurement range (Low/High), hypoglycemia, insufficient sample detection, low/high temperature, low battery.
- Alarm function: 3 daily alarms.
- batteries: two 3Volt batteries, CR2032, included.
- Battery life: 1 year or 1500 measurements.
- Screen: LCD screen.
- Dimensions: 55x100x21 mm
- Weight, meter only: 60 g.
Attention!
Any finger pricker for measuring blood sugar is fine as a lancing device!
-– AutoSense Voice blood glucose monitor with batteries included.
– Adjustable lancing device with disposable lancets.
– 8 lancets, (needles), disposable for lancing device.
– Check card limits, to be used after any maintenance work.
– 10 Autosense test strips.
– Instructions for use.
– Quick start guide for use.
– Synthetic fabric case with zipper.