- Class B fractional vacuum autoclave
-Automatic
- Adjustable sterilization time
- Fast sterilization
- Supports Bowie & Dick test
- Can maintain temperature to speed up subsequent sterilization
- Easy room cleaning
- Easy maintenance
- Easy to use
- Operating temperature: 121° and 134°
Guarantee:
DENEB autoclaves have a 24-month warranty for all customers.
The autoclave is equipped with the following sterilization cycles:
- 121°C - solids - duration 24 minutes
- 121°C - porous bodies - duration 30 minutes
- 121°C - hollow bodies - duration 33 minutes
- 134°C - solids - duration 8 minutes
- 134°C - porous bodies - duration 14 minutes
- 134°C - hollow bodies - duration 17 minutes
- Bowie-Dick test - duration 4 minutes
- Vacuum test - duration 15 minutes
134°C cycles are normally used for the sterilization of solid and ferrous materials. 121°C cycles are used for thermoplastics, textiles, and sensitive materials. Always sterilize the materials according to the instructions given by the device manufacturer.
External dimensions: 58 cm (depth) x 43.5 cm (width) x 36 cm (height)
Chamber diameter: 17 cm
Chamber depth: 32 cm
Chamber volume: 8 liters
Minimum dimensions of the support surface: 35 x 28 cm
Net weight: 34 Kg
Display: LED 2.5 x 2cm, 3.8x 2cm
Door Lock: Mechanical + Electric Lock
Printer: YES
Max Working Pressure: 0.21 - 0.23 MPa
Pressure Sensor Accuracy: 0.1 KPA
Max working temperature: 134 – 137 °C
Temperature Sensor Accuracy: 0.1 °C
Vacuum pump type: double-head
Number of vacuum pumps: 1
Number of water pumps: 1
Number of clean water tanks: 1
Number of waste water tanks: 1
Tank life: 3-4 sterilizations
Number of steam generators: 1
Number of safety valves: 1
Over-temperature protection system: YES
Overpressure protection system: YES
Antibacterial filters: 1
Sterilization Programs:
- 121 °C solids
- 121 °C Porous bodies
- 121 °C hollow bodies
- 134 °C Solids
- 134 °C Porous bodies
- 134 °C hollow bodies
- Bowie & Dick test
- Vacuum Test
Working conditions:
- Ambient temperature: 5 °C - 40 °C
- Relative humidity: ≤80%
- Atmospheric pressure: > 70 kPa
- Voltage: 230VAC, 50Hz, 2500VA
- Maximum working pressure: 0.21 - 0.23 MPa
- Maximum operating temperature: 134 - 137 °C