Description
High-frequency electrosurgical unit that can be used to perform monopolar and bipolar surgery at the same time.
DUAL OPERATIONAL ACTIVITY
- two output channels for monopolar cutting
- Two independent calibrations and channels for the most frequent monopolar coagulations
CONTROLLED CUTTING PROCEDURES
- Intensified cutting currents for eschar-free engraving
- Shear current with coagulating properties for dissection with controlled bleeding
- Low capacitive coupling in endoscopic procedures by means of Slow BLEND current
CONTROLLED DOUBLE COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or pedal
EXTENSIVE BIPOLAR FEATURES
- Bipolar cutting with selectable bleeding control
- BLEND slow shear currents
- Automatic coagulation start and stop can be activated separately
TOTAL SAFETY FOR PATIENT AND SURGEON
- Acceptability of contact impedance between patient body and neutral plate continuously verified by Skin Plate Electronic Control (SPEC)
- Continuous monitoring of the radio frequency leakage current
- Automatically compensated mains voltage variation before starting power and radio frequency delivery
CUSTOMIZED PROCEDURES
- Independent choice of coagulation currents and power levels of each of the two operators
- ten personal procedures that can be configured and immediately recalled
CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- Outputs for pilot-operated connections of argon plasma units and fume extractor
AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of malfunctions found.
- OUTPATIENT SURGERY
- GENERAL SURGERY
- PEDIATRIC SURGERY
-PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
-DERMATOLOGY
-ENDOSCOPY
-GASTROENTEROLOGY
-GYNAECOLOGY
-NEUROSURGERY
-ORTHOPAEDICS
-ENT
-PNEUMOLOGY
-UROLOGY
-VETERINARY
1 pc.
Specifications:
- Maximum out monopolar power pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
- Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
- Maximum out monopolar power coag SPEEDY: 120 W - 500 Ohm
- Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
- Maximum out monopolar power coag SPRAY 100 W - 2000 Ohm
- Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
- Maximum out power bipolar CUT 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
- Working frequency monopolar/bipolar: 425 kHz / 525 kHz
- Patient circuit: F
- Selectable input voltage: 115-230 Vac
- Mains frequency: 50-60 Hz
- Electrical input voltage: 1000 VA
- Size WxHxD: 470 x 150 x 400 mm
- Weight: 17.5 kgs
- Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
- Electrical Class: I CF, MDD 93/42/EC Class: II b
Equipment:
1 - Power cable 5 m
1 - Autoclavable Handpiece with Two Buttons (30536)
5 - Ster. Cold Operated with Two Buttons (30551)
1 - Plate Cable (30559)
5 - Rem disposable plates (30493)
2 - HP double watertight pedal set
3 - Short blade electrode 7 cm
3 - 16 cm long blade electrode
3 - Short ball electrode Ø 4 mm, 6 cm
1 - Electrode cleaning sponge
1 - User Manual (IT, GB)
1 - Service Manual (IT, GB)
DUAL OPERATIONAL ACTIVITY
- two output channels for monopolar cutting
- Two independent calibrations and channels for the most frequent monopolar coagulations
CONTROLLED CUTTING PROCEDURES
- Intensified cutting currents for eschar-free engraving
- Shear current with coagulating properties for dissection with controlled bleeding
- Low capacitive coupling in endoscopic procedures by means of Slow BLEND current
CONTROLLED DOUBLE COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or pedal
EXTENSIVE BIPOLAR FEATURES
- Bipolar cutting with selectable bleeding control
- BLEND slow shear currents
- Automatic coagulation start and stop can be activated separately
TOTAL SAFETY FOR PATIENT AND SURGEON
- Acceptability of contact impedance between patient body and neutral plate continuously verified by Skin Plate Electronic Control (SPEC)
- Continuous monitoring of the radio frequency leakage current
- Automatically compensated mains voltage variation before starting power and radio frequency delivery
CUSTOMIZED PROCEDURES
- Independent choice of coagulation currents and power levels of each of the two operators
- ten personal procedures that can be configured and immediately recalled
CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- Outputs for pilot-operated connections of argon plasma units and fume extractor
AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of malfunctions found.
- OUTPATIENT SURGERY
- GENERAL SURGERY
- PEDIATRIC SURGERY
-PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
-DERMATOLOGY
-ENDOSCOPY
-GASTROENTEROLOGY
-GYNAECOLOGY
-NEUROSURGERY
-ORTHOPAEDICS
-ENT
-PNEUMOLOGY
-UROLOGY
-VETERINARY
1 pc.
Specifications:
- Maximum out monopolar power pure CUT: 400 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ohm
- Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ohm
- Maximum out power monopolar cut ENHANCED: 250 W - 500 Ohm
- Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ohm
- Maximum out monopolar power coag SPEEDY: 120 W - 500 Ohm
- Maximum out power monopolar coag DEEP: 120 W - 200 Ohm
- Maximum out monopolar power coag SPRAY 100 W - 2000 Ohm
- Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ohm
- Maximum out power bipolar CUT 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ohm
- Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ohm
- Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ohm
- Working frequency monopolar/bipolar: 425 kHz / 525 kHz
- Patient circuit: F
- Selectable input voltage: 115-230 Vac
- Mains frequency: 50-60 Hz
- Electrical input voltage: 1000 VA
- Size WxHxD: 470 x 150 x 400 mm
- Weight: 17.5 kgs
- Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2,
- Electrical Class: I CF, MDD 93/42/EC Class: II b
Equipment:
1 - Power cable 5 m
1 - Autoclavable Handpiece with Two Buttons (30536)
5 - Ster. Cold Operated with Two Buttons (30551)
1 - Plate Cable (30559)
5 - Rem disposable plates (30493)
2 - HP double watertight pedal set
3 - Short blade electrode 7 cm
3 - 16 cm long blade electrode
3 - Short ball electrode Ø 4 mm, 6 cm
1 - Electrode cleaning sponge
1 - User Manual (IT, GB)
1 - Service Manual (IT, GB)
Data sheet
6 other products in the same category: