Secure payments
by credit card, Paypal and bank transfer.
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
via Whatsapp + 39.371.43.61.201
Description
Magnetofix are low-frequency magnetotherapy devices, designed and manufactured for outpatient and home applications.
The working frequency of the Magnetofix 30 is variable from 2 to 100 Hz, the maximum magnetic field is 30 Gauss.
The main effects of low-frequency magnetic fields are: Anti-oedema / Analgesic / Antiphlogistic / Regenerative and are mainly used in: Traumatology: pseudoarthrosis and delayed fracture consolidation, fractures at risk of pseudarthrosis, soft tissue injuries (bruises, sprains, burns, etc.), district algodystrophy.
Rheumatology: degenerative rheumatism, inflammatory rheumatism, fibromyalgia rheumatism, aseptic bone necrosis.
Angiology: peripheral arterial disease, sores and ulcers.
Neurology: musculoskeletal headaches, postherpetic neuralgia.
Dermatology: psoriasis, ichthyosis.
Endocrinology: senile and postmenopausal osteoporosis.
The magnetic field produced is impulsive, when the predetermined field strength is reached the field is rapidly cancelled, this rapid change in the field induces in the patient the electromotive forces that determine the stimulating currents.
The apparatus has incorporated a square wave electric current generator with variable frequency from 2 to 100 Hz and variable pulse duration in order to obtain a predetermined and selectable field strength from 5 to 30 Gauss.
The intensity of the magnetic field, as mentioned, is achieved by appropriately modulating the actuation time of the circuit delivering the current in the transducer, this current is monitored by a surveillance circuit managed by an electronic microcontroller that ensures its precision.
The apparatus incorporates a sound and visual magnetic field detector.
Two flat transducers can be connected to the apparatus at the same time, of course in this case the field generated by the single transducer is about half of the total one.
The transducers supplied are made of non-rigid material for a more comfortable application, on the transducers there are slots for fixing by means of elastic bands.
On the transducers the two polarities North (N) and South (S) are indicated, this allows them to be used individually or with a coherent or repulsive concatenated magnetic field.
Specifications:
- Power supply 230 / 50Hz
- Power consumption 22VA
- Internal fuse T 500mA
- Field strength 30 Gauss (3 Mt)
- Frequency 2 => 100Hz
- Applicable Transducers 2
- Type: Plane transducer
- Treatment time from 1 to 60 minutes
- Permanent (00)
- Indicat. Par. Output Alphanumeric Display
- Visual output indicator
- Class of Sic. Electric II BF
- IP20 degree of protection
- Unit Dimensions mm270LX220PX110H
- Weight 1.3 Kg
- Transd. mm160LX100PX30H
- Weight 0.6 Kg
Reference Standards and Directives:
- Directive 93/42/EEC (D.lgs. 46/97)
- Norma Assic. Quality UNI EN ISO 9001 (2000), UNI CEI EN 13485 (2002)
- Safety standards EN60601-1, EN60601-1-2
Equipment:
- 2 Plates 140x95cm
- 2 Sling 8x60 cm
- 1 Headband 8x100cm
The working frequency of the Magnetofix 30 is variable from 2 to 100 Hz, the maximum magnetic field is 30 Gauss.
The main effects of low-frequency magnetic fields are: Anti-oedema / Analgesic / Antiphlogistic / Regenerative and are mainly used in: Traumatology: pseudoarthrosis and delayed fracture consolidation, fractures at risk of pseudarthrosis, soft tissue injuries (bruises, sprains, burns, etc.), district algodystrophy.
Rheumatology: degenerative rheumatism, inflammatory rheumatism, fibromyalgia rheumatism, aseptic bone necrosis.
Angiology: peripheral arterial disease, sores and ulcers.
Neurology: musculoskeletal headaches, postherpetic neuralgia.
Dermatology: psoriasis, ichthyosis.
Endocrinology: senile and postmenopausal osteoporosis.
The magnetic field produced is impulsive, when the predetermined field strength is reached the field is rapidly cancelled, this rapid change in the field induces in the patient the electromotive forces that determine the stimulating currents.
The apparatus has incorporated a square wave electric current generator with variable frequency from 2 to 100 Hz and variable pulse duration in order to obtain a predetermined and selectable field strength from 5 to 30 Gauss.
The intensity of the magnetic field, as mentioned, is achieved by appropriately modulating the actuation time of the circuit delivering the current in the transducer, this current is monitored by a surveillance circuit managed by an electronic microcontroller that ensures its precision.
The apparatus incorporates a sound and visual magnetic field detector.
Two flat transducers can be connected to the apparatus at the same time, of course in this case the field generated by the single transducer is about half of the total one.
The transducers supplied are made of non-rigid material for a more comfortable application, on the transducers there are slots for fixing by means of elastic bands.
On the transducers the two polarities North (N) and South (S) are indicated, this allows them to be used individually or with a coherent or repulsive concatenated magnetic field.
Specifications:
- Power supply 230 / 50Hz
- Power consumption 22VA
- Internal fuse T 500mA
- Field strength 30 Gauss (3 Mt)
- Frequency 2 => 100Hz
- Applicable Transducers 2
- Type: Plane transducer
- Treatment time from 1 to 60 minutes
- Permanent (00)
- Indicat. Par. Output Alphanumeric Display
- Visual output indicator
- Class of Sic. Electric II BF
- IP20 degree of protection
- Unit Dimensions mm270LX220PX110H
- Weight 1.3 Kg
- Transd. mm160LX100PX30H
- Weight 0.6 Kg
Reference Standards and Directives:
- Directive 93/42/EEC (D.lgs. 46/97)
- Norma Assic. Quality UNI EN ISO 9001 (2000), UNI CEI EN 13485 (2002)
- Safety standards EN60601-1, EN60601-1-2
Equipment:
- 2 Plates 140x95cm
- 2 Sling 8x60 cm
- 1 Headband 8x100cm
Data sheet
6 other products in the same category: