PC-3000 Multi-Parameter Monitor
zoom_out_map
chevron_left chevron_right

PC-3000 Multi-Parameter Monitor

795.00 Tax included

757.14 Tax excluded

notifications_active Last items in stock
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)
Description

PC 3000 Multi Parametric Monitor:

- 7'' high-resolution TFT color display, with 5-channel display (various parameter display modes available)
- Standard parameters: ECG, RESP, SpO2, NIBP, 2-TEMP, PR;
- Arrhythmia analysis and ST segment analysis
- Stores up to 800 data sets and 24 hours of ECG tracings
- 480-hour graph and tubular trend for all parameters
- Display shows 7 ECG channels simultaneously
- Protection against interference from defibrillation/electrosurgical unit
- Adult/pediatric measurement mode
- Visual and audible alarms

1 pc.



Specifications:

NIBP Monitoring
- Measurement method: Automatic measurement by oscillation method
- Cuff inflation time: - Initial cuff inflation pressure: Adult and pediatric model: 180mmHg
- Overpressure Protection Limit: Adult and Pediatric Model: 300mmHg

Measurement range
- Systolic blood pressure: Adults and children: 25mmHg – 265mmHg
- Diastolic blood pressure: Adults and children: 12mmHg – 220mmHg
- Mean blood pressure: Adults and children: 18mmHg – 245mmHg
- Measurement accuracy: Systolic +- 10% Diastolic +- 10% MAP +- 10%
- Measurement modes: Manual, Automatic, STAT
- Automatic measurement: 1-240 min
Ranges: Tolerance Ranges:
TEMP monitoring
- Measuring range, accuracy: 15° C – 45° C, +-0.2° C

SpO2 & Pulse Rate Monitoring
- Dual wavelength transducer LED
- SpO2 measuring range 35%-100%
- Low perfusion capacity 0.4% - 5%
- SpO2 Display Accuracy: 90%~99% ±2%, 70%~89% ±4%, 40%~69% ±6%
- PR Measurement Range: 30bpm~250bpm
- PR measurement accuracy: ±2bpm

ECG monitoring
- Heart rate measurement: ±0.4mVp~±3mVp
- Heart rate display range: 20bpm~250bpm
- Display accuracy: ±1% or ± 2 bpm, whichever is greater
- Heart rate delay time alarm: =12s
- Sensitivity selection: Auto, ×1/2, ×1, ×2, ×4 tolerance: =5%
- Speed: 12.5mm/s, 25mm/s, 50mm/s Tolerance: =10%
- ECG noise level: =30μVP-P
- ECG input current: =0.1μA
- Input impedance: =5MO
- Time Constant Monitoring Mode
- Diagnostic mode
- Response Rate Monitoring Mode
- Diagnostic mode

RESP Monitoring
- Measuring range, accuracy: 0rpm~120rpm, ±10%
- RESP alarm field: 0bpm~100bpm
- Alarm tolerance: ±10%

Other technical features
- Power supply: 100~250Vac, 50/60Hz
- Power consumption: - 1.2 inch display, TFT LCD colors
- Alarm mode Visual-acoustic alarms
- Ethernet network port



Equipment:

1 ECG Cable
1 Adult SpO2 Probe
1 AC Power Adapter
1 Li-ion battery
1 NIBP Cuff
1 Body Surface Temperature Sensor
10 disposable electrodes
1 Power Cord
User Manual

Data sheet
GIMA
MN35134
New
6941900604186