K15 touchscreen multiparameter monitor GIMA
K15 MULTI-PARAMETER MONITOR 15" TOUCHSCREEN
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows the complete analysis of the patient's physiological condition.
- Ergonomic design with intuitive user interface
- Secure payments: credit card, Paypal and bank transfer
- Fast shipping: Poste Delivery Express, FedEx, UPS
- Customer support Whatsapp +39 371 43 61 201
Locazione Operativa
Accedi alle migliori tecnologie senza immobilizzare capitali.
| Durata | Canone mensile | Totale |
|---|---|---|
| 24 mesi | €44.83 + IVA | €1,075.92 + IVA |
| 30 mesi | €35.86 + IVA | €1,075.80 + IVA |
| 36 mesi | €31.95 + IVA | €1,150.20 + IVA |
| 48 mesi | €26.61 + IVA | €1,277.28 + IVA |
| 60 mesi | €22.85 + IVA | €1,371.00 + IVA |
* Importi al netto di IVA. Canoni calcolati sul prezzo del prodotto ex-IVA.
📋 Condizioni contrattuali (applicate da Grenke, non in carrello)
- Durata: da 24 a 60 mesi
- Importo noleggiabile: da €500 + IVA
- Pagamento: trimestrale anticipato tramite RID
- Assicurazione: 1,95% annuo sul valore del bene (fatturata direttamente da Grenke)
- Spese di incasso: € 0
-
Spese amministrative:
Fino a €12.500: €75 + IVA €12.501 – €25.000: €90 + IVA €25.001 – €100.000: €100 + IVA Oltre €100.000: €200 + IVA
- Riscatto a scadenza: Restituzione del bene oppure riscatto al 3% del valore iniziale del contratto
- Requisiti: Titolari di Partita IVA con almeno 2 anni di attività, con indirizzo in Italia
Le spese amministrative e assicurative sono gestite direttamente da Grenke e non vengono addebitate dal negozio. I canoni indicati sono stimati sul prezzo del prodotto e potranno essere confermati da Grenke in fase di istruttoria.
K15 TOUCHSCREEN MULTIPARAMETER MONITOR 15" - ECG 5-lead
Multifunction monitor for monitoring the vital physiological signs of adult, pediatric and neonatal patients.
With functions for recording and displaying parameters in real time, such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP) and temperature (TEMP), it enables a comprehensive analysis of the patient's physiological condition.
- ergonomic design with an intuitive user interface
- USB port for data transfer and software updates
- 9 waveform traces on screen
- Windows-style environment, easy to use
- visual and audible alarm for physiological and technical abnormalities
- large memory capacity
- suitable for use with original Nellcor sensors
- protection against defibrillator discharges; resistance to interference from electrosurgical units; detection and inhibition of cardiac pacemaker pulses.
Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.
PC software: GB, IT, ES.
Compatible with Windows XP, 7, 8, 10, 11.
1 piece.
ECG
Input dynamic range: ±(0.5~5 mVp)
Differential input impedance: =10 MO
Bandwidth: 0.05~150 Hz (Diagnostic), 0.5~40 Hz (Monitoring), 1~20 Hz (Operating)
CMRR: =90 dB (Diagnostic) / =105 dB (Monitoring & Operating)
Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
Pacemaker pulse detection and inhibition function
RESP
Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
Measurement range: 21.0~50.0 °C ±0.2 °C between 25~45 °C
NIBP
Technique: Oscillometric method
Typical measurement time: <30 seconds (adult cuff)
NIBP measurement range: SYS: 40~275 mmHg (Adults) / 40~200 mmHg (Pediatric) / 40~135 mmHg (Neonates)
NIBP measurement range: DIA: 10~210 mmHg (Adults) / 10~150 mmHg (Pediatric) / 10~95 mmHg (Neonates)
NIBP measurement range: MAP: 20~230 mmHg (Adults) / 20~165 mmHg (Pediatric) / 20~110 mmHg (Neonates)
NIBP measurement accuracy: Mean difference: ±5 mmHg
Standard deviation: 8 mmHg
NIBP measurement modes: Manual, Auto, STAT, Multicycle
Automatic measurement intervals: 1-480 min
SpO2
Technique: Dual-wavelength optical method
Measurement range: 0%~100% ±2% for SpO2 range 70~100%
PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater
Low perfusion performance: Down to 0.3%.
Other features
Power supply: AC 100-240 V, 50/60 Hz, 60 VA
Built-in lithium battery: 11,1V/4400 mAh
Screen: TFT screen of 12 or 15 inches
Alarm method: 3-level audible-visual alarm
Network: Ethernet
Safety standard: IEC 60601-1
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cable
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES,
- PC software: GB, IT, ES