Gima K15 Touchscreen Multiparameter Monitor - ECG 12 Lead
zoom_out_map
chevron_left chevron_right

Gima K15 Touchscreen Multiparameter Monitor - ECG 12 Lead

€2,277.57 VAT included

€1,866.86 VAT excluded

new_releases Shipping in 7/10 days.
Secure payments
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
Description

K15 MULTIPARAMETER MONITOR TOUCHSCREEN 15" - ECG 10 der.

Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows the complete analysis of the patient's physiological condition.

- Ergonomic design with intuitive user interface
- USB socket for data transfer and software update
- 9 tracks on on-screen waveforms
- Windows-style environment, easy to use
- visual and audible alarm for physiological and technical abnormalities
- Large memory capacity
- Suitable for use with genuine Nellcor sensors
- protection against defibrillator discharges, resistance against interference from electrosurgical units; Detection and inhibition of cardiac pacemaker pulses.

Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.

Software for PC GB, IT, ES.
Compatible with Windows XP, 7, 8, 10, 11.



Specifications:

ECG
Input dynamic range: ±(0.5~5 mVp)
Input differential impedance: =10 MO
Bandwidth: 0.05~150 Hz (Diagnostic), 0.5~40 Hz (Monitoring), 1~20 Hz (Operation)
CMRR: =90 dB (Diagnostic) / =105 dB (Monitoring & Operation)
Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
Pacemaker pulse detection and inhibit function

RESP
Measurement Range: 0~120 rpm ±5% or ±2 rpm, whichever is greater

TEMP
Measurement range: 21.0~50.0°C ±0.2°C between 25~45°C

NIBP
Technique: Oscillometric method
Typical Measurement Time: NIBP Measurement Range: SYS: 40~275 mmHg (Adult) / 40~200 mmHg (Pediatric) / 40~135 mmHg (Neonate)
NIBP Measurement Range: DIA: 10~210 mmHg (Adults) / 10~150 mmHg (Pediatric) / 10~95 mmHg (Neonates)
NIBP Measurement Range: MAP: 20~230 mmHg (Adult) / 20~165 mmHg (Pediatric) / 20~110 mmHg (Neonate)
NIBP Measurement Accuracy: Average Difference: ±5 mmHg
Standard deviation: 8 mmHg
Measurement mode NIBP: Manual, Auto, STAT, Multicycle
Self-measurement intervals: 1-480 min

SpO2
Technique: Dual wavelength optical method
Measurement Range: 0%~100% ±2% for SpO2 Range 70~100%
PR Measurement Range: 30~250bpm ±2bpm or ±2%, whichever is greater
Low perfusion yield: Up to 0.3%.

Other characteristics
Power supply: AC 100-240 V, 50/60 Hz, 60 VA
Built-in lithium battery: 11.1V/4400mAh
Screen: 12 or 15 inch TFT screen
Alarm Method: 3-Level Audible-Visual Alarm
Network: Ethernet
Safety Standard: IEC 60601-1
Standard equipment
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cord
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES,
- PC software: GB, IT, ES

Data sheet
GIMA
MN35332
New