Pre-gelled FOAM electrodes for ECG oval 36x40 mm F9089 - Ag/AgCl - Pack of 100 electrodes

Previous
Next
€7.49
Tax included
Availability Shipping in 1/2 days
Order within 09 h 09 m 32 s for same day shipping!
  • Over 90,000 satisfied customers since 2020
  • Secure payments: credit card, PayPal and bank transfer
  • Expedited shipping: Poste, BRT, FedEx
  • Customer support Whatsapp +39 371 43 61 201
Code ECGXF9089/100 Brand FIAB EAN 8054242449648

Elettromedicali.it presents: Pre-gelled FOAM electrodes for oval ECG 36x40 mm F9089 - Ag/AgCl - Pack of 100 electrodes.

Discover the high quality disposable ECG electrodes from FIAB brand, available on elettromedicali.it. Designed with care and precision, these electrodes offer a reliable solution for recording the electrocardiogram.

Made with an Ag/AgCl (Silver/Silver Chloride) sensor and a stainless steel clip, FIAB disposable electrodes guarantee a stable and precise ECG tracing. Their oval shape of 36x40 mm makes them suitable for use on adults.

These electrodes are ideal for a variety of applications, from resting ECG recording to extended monitoring, from stress testing to Holter use. With their pre-gelled design and waterproof medical grade PE foam outer surface, they effectively protect the skin from airborne contaminants and medical fluids.

FIAB products comply with the ANSI/AAMI EC12:2000 standard, which allows the recovery of the ECG signal even after a defibrillator shock. Furthermore, the packaging bag, once opened, can be closed for optimal conservation of the electrodes remaining inside.

The package contains 100 electrodes, ensuring a sufficient supply for your needs.

Technical features:

- Use: Adults
- Connection: Clip
- Dimensions: 36mm X 40mm (oval)
- Shape: Oval

Test results performed according to the ANSI/AAMI EC12:2000 specification show excellent performance. The impedance measured at 10Hz for 12 pairs of electrodes is an average of 63.8 Ω, ensuring stability and accuracy in the ECG trace. In addition, the residual voltage after defibrillation is only 7.6 mV, ensuring rapid signal recovery.

The maximum values, compliant with the ANSI/AAMI EC12:2000 specification, demonstrate the high quality of these electrodes. The impedance measured at 10Hz for 12 pairs of electrodes is only 2 kΩ, while the residual voltage after defibrillation reaches only 100 mV.

Trust FIAB 's pre-gelled FOAM electrodes for oval ECG 36x40 mm F9089 - Ag/AgCl to obtain precise and reliable results in your ECG recordings. Buy now on elettromedicali.it and guarantee the best care for your patients.

CND: C020501

BD /RDM: 2251898

CLASS: |

Test results according to ANSI/AAMI EC12:2000 specification:
- Average value of impedance measured at 10Hz for 12 pairs of electrodes: 63.8 Ω
- Single pair impedance: 69 Ω
- Offset instability combined with intrinsic noise: 12.6 μV
- Offset Voltage: 0.6mV
- Residual voltage after defibrillation: 7.6 mV
- Polarization variation: 0.17 mV/s
- Impedance at 10 Hz after testing: 63.2 Ω
- Bias current tolerance: 15.2 mV

Maximum values according to ANSI/AAMI EC12:2000 specification:

- Average value of impedance measured at 10Hz for 12 pairs of electrodes: 2 kΩ
- Single pair impedance: 3 kΩ
- Offset instability combined with intrinsic noise: 150 μV
- Offset Voltage: 100mV
- Residual voltage after defibrillation: 100 mV
- Polarization change: 1 mV/s
- Impedance at 10 Hz after testing: 3 kΩ
- Bias current tolerance: 100 mV

Pre-gelled FOAM electrodes for ECG oval 36x40 mm F9089 - Ag/AgCl - Pack of 100 electrodes

4.8 ( 55 )
€7.49
Tax included
  • Over 90,000 satisfied customers since 2020
  • Secure payments: credit card, PayPal and bank transfer
  • Fast shipping: Post and BRT
  • Customer support Whatsapp +39 371 43 61 201
Availability Shipping in 1/2 days
Order within 09 h 09 m 32 s for same day shipping!
Code ECGXF9089/100 Brand FIAB EAN 8054242449648
Share on
Comments (55)
Grade